Latest CVE Feed

Following is the list of latest published vulnerabilities. You can filter the list based on the severity of the vulnerability, whether it is actively exploited (also known as CISA KEV List) or remotely exploitable. You can also sort the list based on the published date, last updated date, or CVSS score.
  • 7.8

    HIGH
    CVE-2021-33004

    The affected product is vulnerable to memory corruption condition due to lack of proper validation of user supplied files, which may allow an attacker to execute arbitrary code. User interaction is required on the WebAccess HMI Designer (versions 2.1.9.95... Read more

    Affected Products : webaccess\/hmi_designer
    • Published: Jun. 24, 2021
    • Modified: Nov. 21, 2024
  • 5.5

    MEDIUM
    CVE-2021-33003

    Delta Electronics DIAEnergie Version 1.7.5 and prior may allow an attacker to retrieve passwords in cleartext due to a weak hashing algorithm.... Read more

    Affected Products : diaenergie
    • Published: Aug. 30, 2021
    • Modified: Nov. 21, 2024
  • 7.8

    HIGH
    CVE-2021-33002

    Opening a maliciously crafted project file may cause an out-of-bounds write, which may allow an attacker to execute arbitrary code. User interaction is require on the WebAccess HMI Designer (versions 2.1.9.95 and prior).... Read more

    Affected Products : webaccess\/hmi_designer
    • Published: Jun. 24, 2021
    • Modified: Nov. 21, 2024
  • 6.1

    MEDIUM
    CVE-2021-33001

    xArrow SCADA versions 7.2 and prior is vulnerable to cross-site scripting due to parameter ‘bdate’ of the resource xhisvalue.htm, which may allow an unauthorized attacker to execute arbitrary code.... Read more

    Affected Products : xarrow
    • Published: May. 16, 2022
    • Modified: Nov. 21, 2024
  • 7.8

    HIGH
    CVE-2021-33000

    Parsing a maliciously crafted project file may cause a heap-based buffer overflow, which may allow an attacker to perform arbitrary code execution. User interaction is required on the WebAccess HMI Designer (versions 2.1.9.95 and prior).... Read more

    Affected Products : webaccess\/hmi_designer
    • Published: Jun. 24, 2021
    • Modified: Nov. 21, 2024
  • 7.5

    HIGH
    CVE-2021-32999

    Improper handling of exceptional conditions in SuiteLink server while processing command 0x01... Read more

    Affected Products : suitelink
    • Published: Sep. 23, 2021
    • Modified: Nov. 21, 2024
  • 8.2

    HIGH
    • Published: May. 25, 2022
    • Modified: Nov. 21, 2024
  • 7.8

    HIGH
    CVE-2021-32995

    Cscape (All Versions prior to 9.90 SP5) lacks proper validation of user-supplied data when parsing project files. This could lead to an out-of-bounds write. An attacker could leverage this vulnerability to execute code in the context of the current proces... Read more

    Affected Products : cscape
    • Published: Aug. 25, 2021
    • Modified: Nov. 21, 2024
  • 7.5

    HIGH
    CVE-2021-32994

    Softing OPC UA C++ SDK (Software Development Kit) versions from 5.59 to 5.64 exported library functions don't properly validate received extension objects, which may allow an attacker to crash the software by sending a variety of specially crafted packets... Read more

    • Published: Apr. 04, 2022
    • Modified: Nov. 21, 2024
  • 8.8

    HIGH
    CVE-2021-32993

    IntelliBridge EC 40 and 60 Hub (C.00.04 and prior) contains hard-coded credentials, such as a password or a cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data.... Read more

    • Published: Dec. 27, 2021
    • Modified: Nov. 21, 2024
  • 9.8

    CRITICAL
    CVE-2021-32992

    FATEK Automation WinProladder Versions 3.30 and prior do not properly restrict operations within the bounds of a memory buffer, which may allow an attacker to execute arbitrary code.... Read more

    Affected Products : winproladder
    • Published: Jun. 29, 2021
    • Modified: Nov. 21, 2024
  • 4.3

    MEDIUM
    CVE-2021-32991

    Delta Electronics DIAEnergie Version 1.7.5 and prior is vulnerable to cross-site request forgery, which may allow an attacker to cause a user to carry out an action unintentionally.... Read more

    Affected Products : diaenergie
    • Published: Aug. 30, 2021
    • Modified: Nov. 21, 2024
  • 9.8

    CRITICAL
    CVE-2021-32990

    FATEK Automation WinProladder Versions 3.30 and prior are vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code.... Read more

    Affected Products : winproladder
    • Published: Jun. 29, 2021
    • Modified: Nov. 21, 2024
  • 9.3

    CRITICAL
    CVE-2021-32989

    When a non-existent resource is requested, the LCDS LAquis SCADA application (version 4.3.1.1011 and prior) returns error messages which may allow reflected cross-site scripting.... Read more

    Affected Products : laquis_scada
    • Published: May. 25, 2022
    • Modified: Nov. 21, 2024
  • 9.8

    CRITICAL
    CVE-2021-32988

    FATEK Automation WinProladder Versions 3.30 and prior are vulnerable to an out-of-bounds write, which may allow an attacker to execute arbitrary code.... Read more

    Affected Products : winproladder
    • Published: Jun. 29, 2021
    • Modified: Nov. 21, 2024
  • 7.5

    HIGH
    CVE-2021-32987

    Null pointer dereference in SuiteLink server while processing command 0x0b... Read more

    Affected Products : suitelink
    • Published: Sep. 23, 2021
    • Modified: Nov. 21, 2024
  • 9.8

    CRITICAL
    CVE-2021-32986

    After Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, the unlocked state does not timeout. If the programming software is interrupted, the PLC remains unlocked. All subsequent programming... Read more

    • Published: Apr. 04, 2022
    • Modified: Nov. 21, 2024
  • 7.2

    HIGH
    CVE-2021-32985

    AVEVA System Platform versions 2017 through 2020 R2 P01 does not properly verify that the source of data or communication is valid.... Read more

    Affected Products : system_platform
    • Published: Apr. 04, 2022
    • Modified: Nov. 21, 2024
  • 9.8

    CRITICAL
    CVE-2021-32984

    All programming connections receive the same unlocked privileges, which can result in a privilege escalation. During the time Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, an attacker c... Read more

    • Published: Apr. 04, 2022
    • Modified: Nov. 21, 2024
  • 10.0

    HIGH
    CVE-2021-32983

    A Blind SQL injection vulnerability exists in the /DataHandler/Handler_CFG.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter keyword b... Read more

    Affected Products : diaenergie
    • Published: Aug. 30, 2021
    • Modified: Nov. 21, 2024
Showing 20 of 293288 Results