Latest CVE Feed
-
9.3
CRITICALCVE-2017-20214
FLIR Thermal Camera F/FC/PT/D firmware version 8.0.0.64 contains hard-coded SSH credentials that cannot be changed through normal camera operations. Attackers can leverage these persistent, unmodifiable credentials to gain unauthorized remote access to th... Read more
Affected Products :- Published: Jan. 08, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Authentication
-
8.7
HIGHCVE-2017-20213
FLIR Thermal Camera F/FC/PT/D Stream firmware version 8.0.0.64 contains an unauthenticated vulnerability that allows remote attackers to access live camera streams without credentials. Attackers can exploit the vulnerability to view unauthorized thermal c... Read more
Affected Products :- Published: Jan. 08, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Authentication
-
8.7
HIGHCVE-2017-20212
FLIR Thermal Camera F/FC/PT/D firmware version 8.0.0.64 contains an information disclosure vulnerability that allows unauthenticated attackers to read arbitrary files through unverified input parameters. Attackers can exploit the /var/www/data/controllers... Read more
Affected Products :- Published: Jan. 08, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Information Disclosure
-
5.4
MEDIUMCVE-2026-21483
listmonk is a standalone, self-hosted, newsletter and mailing list manager. Prior to version 6.0.0, lower-privileged user with campaign management permissions can inject malicious JavaScript into campaigns or templates. When a higher-privileged user (Supe... Read more
Affected Products : listmonk- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Cross-Site Scripting
-
8.7
HIGHCVE-2025-64124
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Nuvation Energy Multi-Stack Controller (MSC) allows OS Command Injection.This issue affects Multi-Stack Controller (MSC): before 2.5.1.... Read more
Affected Products :- Published: Jan. 03, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Injection
-
0.0
NACVE-2025-68751
In the Linux kernel, the following vulnerability has been resolved: s390/fpu: Fix false-positive kmsan report in fpu_vstl() A false-positive kmsan report is detected when running ping command. An inline assembly instruction 'vstl' can write varied amou... Read more
Affected Products : linux_kernel- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Memory Corruption
-
0.0
NACVE-2025-68752
In the Linux kernel, the following vulnerability has been resolved: iavf: Implement settime64 with -EOPNOTSUPP ptp_clock_settime() assumes every ptp_clock has implemented settime64(). Stub it with -EOPNOTSUPP to prevent a NULL dereference. The fix is s... Read more
Affected Products : linux_kernel- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Misconfiguration
-
7.1
HIGHCVE-2025-61781
OpenCTI is an open source platform for managing cyber threat intelligence knowledge and observables. Prior to version 6.8.1, the GraphQL mutation "WorkspacePopoverDeletionMutation" allows users to delete workspace-related objects such as dashboards and in... Read more
Affected Products : opencti- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Authorization
-
0.0
NACVE-2025-68754
In the Linux kernel, the following vulnerability has been resolved: rtc: amlogic-a4: fix double free caused by devm The clock obtained via devm_clk_get_enabled() is automatically managed by devres and will be disabled and freed on driver detach. Manuall... Read more
Affected Products : linux_kernel- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Memory Corruption
-
0.0
NACVE-2025-68762
In the Linux kernel, the following vulnerability has been resolved: net: netpoll: initialize work queue before error checks Prevent a kernel warning when netconsole setup fails on devices with IFF_DISABLE_NETPOLL flag. The warning (at kernel/workqueue.c... Read more
Affected Products : linux_kernel- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Misconfiguration
-
5.3
MEDIUMCVE-2025-12519
Missing Authorization vulnerability in Centreon Infra Monitoring (Administration parameters API endpoint modules) allows Accessing Functionality Not Properly Constrained by ACLs, resulting in Information Disclosure like downtime or acknowledgement configu... Read more
Affected Products :- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Authorization
-
8.5
HIGHCVE-2025-69414
Plex Media Server (PMS) through 1.42.2.10156 allows retrieval of a permanent access token via a /myplex/account call with a transient access token.... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Authentication
-
7.2
HIGHCVE-2025-5965
In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Bac... Read more
Affected Products :- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Injection
-
5.3
MEDIUMCVE-2026-0571
A security flaw has been discovered in yeqifu warehouse up to aaf29962ba407d22d991781de28796ee7b4670e4. Affected by this issue is the function createResponseEntity of the file warehouse\src\main\java\com\yeqifu\sys\common\AppFileUtils.java. The manipulati... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Path Traversal
-
9.4
CRITICALCVE-2025-64125
A vulnerability in Nuvation Energy nCloud VPN Service allowed Network Boundary Bridging.This issue affected the nCloud VPN Service and was fixed on 2025-12-1 (December, 2025). End users do not have to take any action to mitigate the issue.... Read more
Affected Products :- Published: Jan. 03, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Misconfiguration
-
5.4
MEDIUMCVE-2025-67316
An issue in realme Internet browser v.45.13.4.1 allows a remote attacker to execute arbitrary code via a crafted webpage in the built-in HeyTap/ColorOS browser... Read more
Affected Products :- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
-
7.8
HIGHCVE-2025-57836
An issue was discovered in Samsung Magician 6.3.0 through 8.3.2 on Windows. The installer creates a temporary folder with weak permissions during installation, allowing a non-admin user to perform DLL hijacking and escalate privileges.... Read more
Affected Products :- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Misconfiguration
-
7.1
HIGHCVE-2025-52519
An issue was discovered in the Camera in Samsung Mobile Processor and Wearable Processor Exynos 1330, 1380, 1480, 2400, 1580, and 2500. Improper validation of user-space input in the issimian device driver leads to information disclosure and a denial of s... Read more
Affected Products :- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Information Disclosure
-
5.0
MEDIUMCVE-2025-69417
In the plex.tv backend for Plex Media Server (PMS) through 2025-12-31, a non-server device token can retrieve share tokens (intended for unrelated access) via a shared_servers endpoint.... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Authentication
-
7.1
HIGHCVE-2025-69415
In Plex Media Server (PMS) through 1.42.2.10156, ability to access /myplex/account with a device token is not properly aligned with whether the device is currently associated with an account.... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Authentication