Latest CVE Feed
-
6.1
MEDIUMCVE-2019-25284
V-SOL GPON/EPON OLT Platform v2.03 contains multiple reflected cross-site scripting vulnerabilities due to improper input sanitization in various script parameters. Attackers can exploit these vulnerabilities by injecting malicious HTML and script code to... Read more
Affected Products :- Published: Jan. 08, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Cross-Site Scripting
-
6.1
MEDIUMCVE-2019-25280
Yahei-PHP Prober 0.4.7 contains a remote HTML injection vulnerability that allows attackers to execute arbitrary HTML code through the 'speed' GET parameter. Attackers can inject malicious HTML code in the 'speed' parameter of prober.php to trigger cross-... Read more
Affected Products :- Published: Jan. 08, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Cross-Site Scripting
-
6.1
MEDIUMCVE-2019-25270
SOCA Access Control System 180612 contains a cross-site scripting vulnerability in the 'senddata' POST parameter of logged_page.php that allows attackers to inject malicious scripts. Attackers can exploit this weakness by sending crafted POST requests to ... Read more
Affected Products :- Published: Jan. 08, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Cross-Site Scripting
-
9.8
CRITICALCVE-2017-20216
FLIR Thermal Camera PT-Series firmware version 8.0.0.64 contains multiple unauthenticated remote command injection vulnerabilities in the controllerFlirSystem.php script. Attackers can execute arbitrary system commands as root by exploiting unsanitized PO... Read more
Affected Products :- Published: Jan. 08, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Injection
-
8.8
HIGHCVE-2017-20215
FLIR Thermal Camera FC-S/PT firmware version 8.0.0.64 contains an authenticated OS command injection vulnerability that allows attackers to execute shell commands with root privileges. Authenticated attackers can inject arbitrary shell commands through un... Read more
Affected Products :- Published: Jan. 08, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Injection
-
9.3
CRITICALCVE-2017-20214
FLIR Thermal Camera F/FC/PT/D firmware version 8.0.0.64 contains hard-coded SSH credentials that cannot be changed through normal camera operations. Attackers can leverage these persistent, unmodifiable credentials to gain unauthorized remote access to th... Read more
Affected Products :- Published: Jan. 08, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Authentication
-
8.7
HIGHCVE-2017-20213
FLIR Thermal Camera F/FC/PT/D Stream firmware version 8.0.0.64 contains an unauthenticated vulnerability that allows remote attackers to access live camera streams without credentials. Attackers can exploit the vulnerability to view unauthorized thermal c... Read more
Affected Products :- Published: Jan. 08, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Authentication
-
8.7
HIGHCVE-2017-20212
FLIR Thermal Camera F/FC/PT/D firmware version 8.0.0.64 contains an information disclosure vulnerability that allows unauthenticated attackers to read arbitrary files through unverified input parameters. Attackers can exploit the /var/www/data/controllers... Read more
Affected Products :- Published: Jan. 08, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Information Disclosure
-
5.3
MEDIUMCVE-2025-10933
An integer underflow vulnerability in the Silicon Labs Z-Wave Protocol Controller can lead to out of bounds memory reads.... Read more
Affected Products :- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Memory Corruption
-
6.9
MEDIUMCVE-2025-3654
Petlibro Smart Pet Feeder Platform versions up to 1.7.31 contains an information disclosure vulnerability that allows unauthorized access to device hardware information by exploiting insecure API endpoints. Attackers can retrieve device serial numbers and... Read more
Affected Products :- Published: Jan. 04, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Information Disclosure
-
9.4
CRITICALCVE-2025-64125
A vulnerability in Nuvation Energy nCloud VPN Service allowed Network Boundary Bridging.This issue affected the nCloud VPN Service and was fixed on 2025-12-1 (December, 2025). End users do not have to take any action to mitigate the issue.... Read more
Affected Products :- Published: Jan. 03, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Misconfiguration
-
5.4
MEDIUMCVE-2026-21483
listmonk is a standalone, self-hosted, newsletter and mailing list manager. Prior to version 6.0.0, lower-privileged user with campaign management permissions can inject malicious JavaScript into campaigns or templates. When a higher-privileged user (Supe... Read more
Affected Products : listmonk- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Cross-Site Scripting
-
8.5
HIGHCVE-2025-69414
Plex Media Server (PMS) through 1.42.2.10156 allows retrieval of a permanent access token via a /myplex/account call with a transient access token.... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Authentication
-
5.0
MEDIUMCVE-2025-69416
In the plex.tv backend for Plex Media Server (PMS) through 2025-12-31, a non-server device token can retrieve other tokens (intended for unrelated access) via clients.plex.tv/devices.xml.... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Information Disclosure
-
6.5
MEDIUMCVE-2025-15448
A vulnerability was found in cld378632668 JavaMall up to 994f1e2b019378ec9444cdf3fce2d5b5f72d28f0. This impacts the function Upload of the file src/main/java/com/macro/mall/controller/MinioController.java. The manipulation results in unrestricted upload. ... Read more
Affected Products :- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Misconfiguration
-
0.0
NACVE-2025-68754
In the Linux kernel, the following vulnerability has been resolved: rtc: amlogic-a4: fix double free caused by devm The clock obtained via devm_clk_get_enabled() is automatically managed by devres and will be disabled and freed on driver detach. Manuall... Read more
Affected Products : linux_kernel- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Memory Corruption
-
6.5
MEDIUMCVE-2025-65328
Mega-Fence (webgate-lib.*) 25.1.914 and prior trusts the first value of the X-Forwarded-For (XFF) header as the client IP without validating a trusted proxy chain. An attacker can supply an arbitrary XFF value in a remote request to spoof the client IP, w... Read more
Affected Products :- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Misconfiguration
-
7.5
HIGHCVE-2025-67158
An authentication bypass in the /cgi-bin/jvsweb.cgi endpoint of Revotech I6032W-FHW v1.0.0014 - 20210517 allows attackers to access sensitive information and escalate privileges via a crafted HTTP request.... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Authentication
-
7.5
HIGHCVE-2025-67160
An issue in Vatilon v1.12.37-20240124 allows attackers to access sensitive directories and files via a directory traversal.... Read more
Affected Products :- Published: Jan. 02, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Path Traversal
-
6.5
MEDIUMCVE-2026-21634
A malicious actor with access to the adjacent network could overflow the UniFi Protect Application (Version 6.1.79 and earlier) discovery protocol causing it to restart. Affected Products: UniFi Protect Application (Version 6.1.79 and earlier). ... Read more
Affected Products : unifi_protect- Published: Jan. 05, 2026
- Modified: Jan. 08, 2026
- Vuln Type: Denial of Service