Latest CVE Feed
-
4.7
MEDIUMCVE-2024-12973
Origin Validation Error vulnerability in Akinsoft OctoCloud allows HTTP Response Splitting, CAPEC - 87 - Forceful Browsing.This issue affects OctoCloud: from s1.09.01 before v1.11.01.... Read more
Affected Products :- Published: Sep. 02, 2025
- Modified: Sep. 02, 2025
- Vuln Type: Misconfiguration
-
9.3
CRITICALCVE-2025-52551
E2 Facility Management Systems use a proprietary protocol that allows for unauthenticated file operations on any file in the file system.... Read more
Affected Products :- Published: Sep. 02, 2025
- Modified: Sep. 02, 2025
- Vuln Type: Authentication
-
5.3
MEDIUMCVE-2025-52543
E3 Site Supervisor Control (firmware version < 2.31F01) application services (MGW and RCI) uses client side hashing for authentication. An attacker can authenticate by obtaining only the password hash.... Read more
Affected Products :- Published: Sep. 02, 2025
- Modified: Sep. 02, 2025
- Vuln Type: Authentication
-
8.7
HIGHCVE-2025-52547
E3 Site Supervisor Control (firmware version < 2.31F01) MGW contains an API call that lacks input validation. An attacker can use this command to continuously crash the application services.... Read more
Affected Products :- Published: Sep. 02, 2025
- Modified: Sep. 02, 2025
- Vuln Type: Denial of Service
-
5.5
MEDIUMCVE-2025-5083
The Amministrazione Trasparente plugin for WordPress is vulnerable to Stored Cross-Site Scripting via admin settings in all versions up to, and including, 9.0 due to insufficient input sanitization and output escaping. This makes it possible for authentic... Read more
Affected Products : amministrazione_trasparente- Published: Aug. 31, 2025
- Modified: Sep. 02, 2025
- Vuln Type: Cross-Site Scripting
-
8.8
HIGHCVE-2025-52544
E3 Site Supervisor Control (firmware version < 2.31F01) has a floor plan feature that allows for an unauthenticated attacker to upload floor plan files. By uploading a specially crafted floor plan file, an attacker can access any file from the E3 file sys... Read more
Affected Products :- Published: Sep. 02, 2025
- Modified: Sep. 02, 2025
- Vuln Type: Path Traversal
-
5.1
MEDIUMCVE-2025-52546
E3 Site Supervisor Control (firmware version < 2.31F01) has a floor plan feature that allows for an unauthenticated attacker to upload floor plan files. By uploading a specially crafted floor plan file, an attacker can inject a stored XSS to the floorplan... Read more
Affected Products :- Published: Sep. 02, 2025
- Modified: Sep. 02, 2025
- Vuln Type: Cross-Site Scripting
-
9.8
CRITICALCVE-2025-6507
A vulnerability in the h2oai/h2o-3 repository allows attackers to exploit deserialization of untrusted data, potentially leading to arbitrary code execution and reading of system files. This issue affects the latest master branch version 3.47.0.99999. The... Read more
Affected Products : h2o- Published: Sep. 01, 2025
- Modified: Sep. 02, 2025
- Vuln Type: Misconfiguration
-
4.3
MEDIUMCVE-2024-12974
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Akinsoft ProKuaför allows Cross-Site Scripting (XSS).This issue affects ProKuaför: from s1.02.07 before v1.02.08.... Read more
Affected Products :- Published: Sep. 02, 2025
- Modified: Sep. 02, 2025
- Vuln Type: Cross-Site Scripting
-
7.8
HIGHCVE-2025-58178
SonarQube Server and Cloud is a static analysis solution for continuous code quality and security inspection. In versions 4 to 5.3.0, a command injection vulnerability was discovered in the SonarQube Scan GitHub Action that allows untrusted input argument... Read more
Affected Products :- Published: Sep. 02, 2025
- Modified: Sep. 02, 2025
- Vuln Type: Injection
-
7.5
HIGHCVE-2025-7731
Cleartext Transmission of Sensitive Information vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series CPU module allows a remote unauthenticated attacker to obtain credential information by intercepting SLMP communication messages, and read ... Read more
Affected Products : melsec_iq-fx5u-32mt\/es_firmware melsec_iq-fx5u-32mt\/ds_firmware melsec_iq-fx5u-32mt\/ess_firmware melsec_iq-fx5u-32mt\/dss_firmware melsec_iq-fx5u-32mr\/es_firmware melsec_iq-fx5u-32mr\/ds_firmware melsec_iq-fx5u-64mt\/es_firmware melsec_iq-fx5u-64mt\/ds_firmware melsec_iq-fx5u-64mt\/ess_firmware melsec_iq-fx5u-64mt\/dss_firmware +11 more products- Published: Sep. 01, 2025
- Modified: Sep. 02, 2025
- Vuln Type: Information Disclosure
-
10.0
CRITICALCVE-2009-20011
ContentKeeper Web Appliance (now maintained by Impero Software) versions prior to 125.10 are vulnerable to remote command execution due to insecure handling of file uploads via the mimencode CGI utility. The vulnerability allows unauthenticated attackers ... Read more
Affected Products :- Published: Aug. 30, 2025
- Modified: Sep. 02, 2025
- Vuln Type: Authentication
-
9.2
CRITICALCVE-2025-52549
E3 Site Supervisor Control (firmware version < 2.31F01) generates the root linux password on each boot. An attacker can generate the root linux password for a vulnerable device based on known or easy to fetch parameters.... Read more
Affected Products :- Published: Sep. 02, 2025
- Modified: Sep. 02, 2025
- Vuln Type: Cryptography
-
9.8
CRITICALCVE-2022-38696
In BootRom, there's a possible missing payload size check. This could lead to memory buffer overflow without requiring additional execution privileges.... Read more
Affected Products :- Published: Sep. 01, 2025
- Modified: Sep. 02, 2025
- Vuln Type: Memory Corruption
-
7.8
HIGHCVE-2022-38695
In BootRom, there's a possible unchecked command index. This could lead to local escalation of privilege with no additional execution privileges needed.... Read more
Affected Products :- Published: Sep. 01, 2025
- Modified: Sep. 02, 2025
- Vuln Type: Authorization
-
4.8
MEDIUMCVE-2025-9797
A vulnerability was determined in mrvautin expressCart up to b31302f4e99c3293bd742c6d076a721e168118b0. This impacts an unknown function of the file /admin/product/edit/ of the component Edit Product Page. This manipulation causes injection. The attack can... Read more
Affected Products :- Published: Sep. 01, 2025
- Modified: Sep. 02, 2025
- Vuln Type: Injection
-
6.5
MEDIUMCVE-2025-9727
A weakness has been identified in D-Link DIR-816L 206b01. Affected by this issue is the function soapcgi_main of the file /soap.cgi. This manipulation of the argument service causes os command injection. Remote exploitation of the attack is possible. The ... Read more
Affected Products :- Published: Aug. 31, 2025
- Modified: Sep. 02, 2025
- Vuln Type: Injection
-
8.6
HIGHCVE-2025-0610
Cross-Site Request Forgery (CSRF) vulnerability in Akınsoft QR Menü allows Cross Site Request Forgery.This issue affects QR Menü: from s1.05.06 before v1.05.12.... Read more
Affected Products :- Published: Sep. 01, 2025
- Modified: Sep. 02, 2025
- Vuln Type: Cross-Site Request Forgery
-
9.8
CRITICALCVE-2025-54857
Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in SkyBridge BASIC MB-A130 Ver.1.5.8 and earlier. If exploited, a remote unauthenticated attacker may execute arbitrary OS commands with root privilege... Read more
Affected Products : skybridge_basic_mb-a130_firmware- Published: Sep. 01, 2025
- Modified: Sep. 02, 2025
- Vuln Type: Injection
-
7.4
HIGHCVE-2025-41690
A low-privileged attacker in bluetooth range may be able to access the password of a higher-privilege user (Maintenance) by viewing the device’s event log. This vulnerability could allow the Operator to authenticate as the Maintenance user, thereby gainin... Read more
Affected Products :- Published: Sep. 02, 2025
- Modified: Sep. 02, 2025
- Vuln Type: Information Disclosure