Latest CVE Feed
-
9.1
CRITICALCVE-2025-59703
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a Physically Proximate Attacker to access the internal components of the appliance, without leaving tamper evidence. To exploit this, the attacker needs to remove the... Read more
- Published: Dec. 02, 2025
- Modified: Dec. 08, 2025
- Vuln Type: Authentication
-
4.6
MEDIUMCVE-2025-59704
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow an attacker to gain access the the BIOS menu because is has no password.... Read more
- Published: Dec. 02, 2025
- Modified: Dec. 08, 2025
- Vuln Type: Misconfiguration
-
9.8
CRITICALCVE-2025-66208
Collabora Online - Built-in CODE Server (richdocumentscode) provides a built-in server with all of the document editing features of Collabora Online. In versions prior to 25.04.702, Collabora Online has a Configuration-Dependent RCE (OS Command Injection)... Read more
Affected Products : online- Published: Dec. 03, 2025
- Modified: Dec. 08, 2025
- Vuln Type: Injection
-
8.3
HIGHCVE-2025-58098
Apache HTTP Server 2.4.65 and earlier with Server Side Includes (SSI) enabled and mod_cgid (but not mod_cgi) passes the shell-escaped query string to #exec cmd="..." directives. This issue affects Apache HTTP Server before 2.4.66. Users are recommended ... Read more
Affected Products : http_server- Published: Dec. 05, 2025
- Modified: Dec. 08, 2025
- Vuln Type: Injection
-
5.5
MEDIUMCVE-2025-66334
Denial of service (DoS) vulnerability in the office service. Impact: Successful exploitation of this vulnerability may affect availability.... Read more
Affected Products : harmonyos- Published: Dec. 08, 2025
- Modified: Dec. 08, 2025
- Vuln Type: Denial of Service
-
7.2
HIGHCVE-2025-59697
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a physically proximate attacker to escalate privileges by editing the Legacy GRUB bootloader configuration to start a root shell upon boot of the host OS. This is cal... Read more
- Published: Dec. 02, 2025
- Modified: Dec. 08, 2025
- Vuln Type: Authentication
-
3.2
LOWCVE-2025-59696
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a physically proximate attacker to modify or erase tamper events via the Chassis management board.... Read more
- Published: Dec. 02, 2025
- Modified: Dec. 08, 2025
- Vuln Type: Misconfiguration
-
7.5
HIGHCVE-2025-54848
A denial of service vulnerability exists in the Modbus TCP and Modbus RTU over TCP functionality of Socomec DIRIS Digiware M-70 1.6.9. A specially crafted series of network requests can lead to a denial of service. An attacker can send a sequence of unaut... Read more
- Published: Dec. 01, 2025
- Modified: Dec. 08, 2025
- Vuln Type: Denial of Service
-
7.5
HIGHCVE-2025-54849
A denial of service vulnerability exists in the Modbus TCP and Modbus RTU over TCP functionality of Socomec DIRIS Digiware M-70 1.6.9. A specially crafted series of network requests can lead to a denial of service. An attacker can send a sequence of unaut... Read more
- Published: Dec. 01, 2025
- Modified: Dec. 08, 2025
- Vuln Type: Denial of Service
-
6.4
MEDIUMCVE-2025-59788
Cross-site scripting (XSS) vulnerability in a reachable files_pdfviewer example directory in Nextcloud with versions before 22.2.10.33, 23.0.12.29, 24.0.12.28, 25.0.13.23, 26.0.13.20, 27.1.11.20, 28.0.14.11, 29.0.16.8, 30.0.17, 31.0.10, and 32.0.1 allows ... Read more
Affected Products : nextcloud- Published: Dec. 04, 2025
- Modified: Dec. 08, 2025
- Vuln Type: Cross-Site Scripting
-
1.8
LOWCVE-2025-66479
Anthropic Sandbox Runtime is a lightweight sandboxing tool for enforcing filesystem and network restrictions on arbitrary processes at the OS level, without requiring a container. Prior to 0.0.16, due to a bug in sandboxing logic, sandbox-runtime did not ... Read more
Affected Products :- Published: Dec. 04, 2025
- Modified: Dec. 08, 2025
- Vuln Type: Misconfiguration
-
8.7
HIGHCVE-2025-12097
There is a relative path traversal vulnerability in the NI System Web Server that may result in information disclosure. Successful exploitation requires an attacker to send a specially crafted request to the NI System Web Server, allowing the attacker to... Read more
Affected Products : labview- Published: Dec. 04, 2025
- Modified: Dec. 08, 2025
- Vuln Type: Path Traversal
-
9.3
CRITICALCVE-2025-66571
UNA CMS versions 9.0.0-RC1 - 14.0.0-RC4 contain a PHP object injection vulnerability in BxBaseMenuSetAclLevel.php where the profile_id POST parameter is passed to PHP unserialize() without proper handling, allowing remote, unauthenticated attackers to inj... Read more
Affected Products :- Published: Dec. 04, 2025
- Modified: Dec. 08, 2025
- Vuln Type: Injection
-
7.4
HIGHCVE-2025-66238
DCIM dcTrack allows an attacker to misuse certain remote access features. An authenticated user with access to the appliance's virtual console could exploit these features to redirect network traffic, potentially accessing restricted services or data on t... Read more
Affected Products :- Published: Dec. 04, 2025
- Modified: Dec. 08, 2025
- Vuln Type: Server-Side Request Forgery
-
7.4
HIGHCVE-2025-10285
The web interface of the Silicon Labs Simplicity Device Manager is exposed publicly and can be used to extract the NTLMv2 hash which an attacker could use to crack the user's domain password.... Read more
Affected Products :- Published: Dec. 04, 2025
- Modified: Dec. 08, 2025
- Vuln Type: Information Disclosure
-
8.3
HIGHCVE-2025-13932
The SolisCloud API suffers from a Broken Access Control vulnerability, specifically an Insecure Direct Object Reference (IDOR), where any authenticated user can access detailed data of any plant by altering the plant_id in the request.... Read more
Affected Products :- Published: Dec. 04, 2025
- Modified: Dec. 08, 2025
- Vuln Type: Authorization
-
8.7
HIGHCVE-2025-13373
Advantech iView versions 5.7.05.7057 and prior do not properly sanitize SNMP v1 trap (Port 162) requests, which could allow an attacker to inject SQL commands.... Read more
Affected Products : iview- Published: Dec. 04, 2025
- Modified: Dec. 08, 2025
- Vuln Type: Injection
-
4.7
MEDIUMCVE-2025-32898
The KDE Connect verification-code protocol before 2025-04-18 uses only 8 characters and therefore allows brute-force attacks. This affects KDE Connect before 1.33.0 on Android, KDE Connect before 25.04 on desktop, KDE Connect before 0.5 on iOS, Valent bef... Read more
Affected Products :- Published: Dec. 05, 2025
- Modified: Dec. 08, 2025
- Vuln Type: Authentication
-
4.7
MEDIUMCVE-2025-66270
The KDE Connect protocol 8 before 2025-11-28 does not correlate device IDs across two packets. This affects KDE Connect before 25.12 on desktop, KDE Connect before 0.5.4 on iOS, KDE Connect before 1.34.4 on Android, GSConnect before 68, and Valent before ... Read more
Affected Products :- Published: Dec. 05, 2025
- Modified: Dec. 08, 2025
- Vuln Type: Information Disclosure
-
4.4
MEDIUMCVE-2025-12124
The FitVids for WordPress plugin for WordPress is vulnerable to Stored Cross-Site Scripting via admin settings in all versions up to, and including, 4.0.1 due to insufficient input sanitization and output escaping. This makes it possible for authenticated... Read more
Affected Products :- Published: Dec. 05, 2025
- Modified: Dec. 08, 2025
- Vuln Type: Cross-Site Scripting