Latest CVE Feed
-
8.6
HIGHCVE-2024-39368
Improper neutralization of special elements used in an SQL command ('SQL Injection') in some Intel(R) Neural Compressor software before version v3.0 may allow an authenticated user to potentially enable escalation of privilege via adjacent access.... Read more
Affected Products :- Published: Nov. 13, 2024
- Modified: Nov. 15, 2024
-
6.8
MEDIUMCVE-2024-28049
Improper input validation in firmware for some Intel(R) PROSet/Wireless Software and Intel(R) Killer(TM) Wi-Fi wireless products before version 23.40 may allow an unauthenticated user to enable denial of service via adjacent access.... Read more
Affected Products :- Published: Nov. 13, 2024
- Modified: Nov. 15, 2024
-
6.7
MEDIUMCVE-2024-28881
Uncontrolled search path for some Intel(R) Fortran Compiler Classic software before version 2021.13 may allow an authenticated user to potentially enable escalation of privilege via local access.... Read more
Affected Products :- Published: Nov. 13, 2024
- Modified: Nov. 15, 2024
-
6.8
MEDIUMCVE-2024-24984
Improper input validation for some Intel(R) Wireless Bluetooth(R) products for Windows before version 23.40 may allow an unauthenticated user to potentially enable denial of service via adjacent access.... Read more
Affected Products :- Published: Nov. 13, 2024
- Modified: Nov. 15, 2024
-
2.2
LOWCVE-2024-28051
Out-of-bounds read in some Intel(R) VPL software before version 24.1.4 may allow an authenticated user to potentially enable information disclosure via local access.... Read more
Affected Products :- Published: Nov. 13, 2024
- Modified: Nov. 15, 2024
-
4.6
MEDIUMCVE-2024-25563
Improper initialization in firmware for some Intel(R) PROSet/Wireless Software and Intel(R) Killer(TM) Wi-Fi before version 23.40 may allow a privileged user to potentially enable information disclosure via local access.... Read more
Affected Products :- Published: Nov. 13, 2024
- Modified: Nov. 15, 2024
-
5.1
MEDIUMCVE-2024-7787
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in ITG Computer Technology vSRM Supplier Relationship Management System allows Reflected XSS, Cross-Site Scripting (XSS).This issue affects vSRM Supp... Read more
Affected Products :- Published: Nov. 14, 2024
- Modified: Nov. 15, 2024
-
10.0
CRITICALCVE-2024-52379
Unrestricted Upload of File with Dangerous Type vulnerability in Kinetic Innovative Technologies Sdn Bhd kineticPay for WooCommerce allows Upload a Web Shell to a Web Server.This issue affects kineticPay for WooCommerce: from n/a through 2.0.8.... Read more
Affected Products :- Published: Nov. 14, 2024
- Modified: Nov. 15, 2024
-
10.0
CRITICALCVE-2024-52374
Unrestricted Upload of File with Dangerous Type vulnerability in DoThatTask Do That Task allows Upload a Web Shell to a Web Server.This issue affects Do That Task: from n/a through 1.5.5.... Read more
Affected Products :- Published: Nov. 14, 2024
- Modified: Nov. 15, 2024
-
7.1
HIGHCVE-2024-51658
Cross-Site Request Forgery (CSRF) vulnerability in Henrik Hoff WP Course Manager allows Stored XSS.This issue affects WP Course Manager: from n/a through 1.3.... Read more
Affected Products :- Published: Nov. 14, 2024
- Modified: Nov. 15, 2024
-
9.3
CRITICALCVE-2024-48971
The Clinician Password and Serial Number Clinician Password are hard-coded into the ventilator in plaintext form. This could allow an attacker to obtain the password off the ventilator and use it to gain unauthorized access to the device, with clinician p... Read more
Affected Products :- Published: Nov. 14, 2024
- Modified: Nov. 15, 2024
-
9.9
CRITICALCVE-2024-52369
Unrestricted Upload of File with Dangerous Type vulnerability in Optimal Access Inc. KBucket allows Upload a Web Shell to a Web Server.This issue affects KBucket: from n/a through 4.1.6.... Read more
Affected Products :- Published: Nov. 14, 2024
- Modified: Nov. 15, 2024
-
10.0
CRITICALCVE-2024-48967
The ventilator and the Service PC lack sufficient audit logging capabilities to allow for detection of malicious activity and subsequent forensic examination. An attacker with access to the ventilator and/or the Service PC could, without detection, make u... Read more
Affected Products :- Published: Nov. 14, 2024
- Modified: Nov. 15, 2024
-
9.3
CRITICALCVE-2024-9832
There is no limit on the number of failed login attempts permitted with the Clinician Password or the Serial Number Clinician Password. An attacker could execute a brute-force attack to gain unauthorized access to the ventilator, and then make changes to ... Read more
Affected Products :- Published: Nov. 14, 2024
- Modified: Nov. 15, 2024
-
7.5
HIGHCVE-2024-45254
VaeMendis - CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')... Read more
Affected Products :- Published: Nov. 14, 2024
- Modified: Nov. 15, 2024
-
9.3
CRITICALCVE-2024-48974
The ventilator does not perform proper file integrity checks when adopting firmware updates. This makes it possible for an attacker to force unauthorized changes to the device's configuration settings and/or compromise device functionality by pushing a co... Read more
Affected Products :- Published: Nov. 14, 2024
- Modified: Nov. 15, 2024
-
7.5
HIGHCVE-2024-47916
Boa web server - CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')... Read more
Affected Products :- Published: Nov. 14, 2024
- Modified: Nov. 15, 2024
-
7.1
HIGHCVE-2024-51688
Cross-Site Request Forgery (CSRF) vulnerability in FraudLabs Pro FraudLabs Pro SMS Verification allows Stored XSS.This issue affects FraudLabs Pro SMS Verification: from n/a through 1.10.1.... Read more
Affected Products :- Published: Nov. 14, 2024
- Modified: Nov. 15, 2024
-
9.3
CRITICALCVE-2024-48973
The debug port on the ventilator's serial interface is enabled by default. This could allow an attacker to send and receive messages over the debug port (which are unencrypted; see 3.2.1) that result in unauthorized disclosure of information and/or have u... Read more
Affected Products :- Published: Nov. 14, 2024
- Modified: Nov. 15, 2024
-
10.0
CRITICALCVE-2024-48966
The software tools used by service personnel to test & calibrate the ventilator do not support user authentication. An attacker with access to the Service PC where the tools are installed could obtain diagnostic information through the test tool or manipu... Read more
Affected Products :- Published: Nov. 14, 2024
- Modified: Nov. 15, 2024