6.8
MEDIUM
CVE-2015-8561
Schneider Electric ProClima F1BookView Remote Code Execution Memory Corruption Vulnerability
Description

The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a denial of service (memory corruption) via a crafted integer value to the (1) AttachToSS, (2) CopyAll, (3) CopyRange, (4) CopyRangeEx, or (5) SwapTable method, a different vulnerability than CVE-2015-7918.

INFO

Published Date :

Dec. 15, 2015, 5:59 a.m.

Last Modified :

Nov. 21, 2024, 2:38 a.m.

Remotely Exploitable :

Yes !

Impact Score :

6.4

Exploitability Score :

8.6
Affected Products

The following products are affected by CVE-2015-8561 vulnerability. Even if cvefeed.io is aware of the exact versions of the products that are affected, the information is not represented in the table below.

ID Vendor Product Action
1 Schneider-electric proclima

We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).

Results are limited to the first 15 repositories due to potential performance issues.

The following list is the news that have been mention CVE-2015-8561 vulnerability anywhere in the article.

The following table lists the changes that have been made to the CVE-2015-8561 vulnerability over time.

Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.

  • CVE Modified by af854a3a-2127-422b-91ae-364da2661108

    Nov. 21, 2024

    Action Type Old Value New Value
    Added Reference http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-329-01
    Added Reference http://www.zerodayinitiative.com/advisories/ZDI-15-626
    Added Reference http://www.zerodayinitiative.com/advisories/ZDI-15-627
    Added Reference http://www.zerodayinitiative.com/advisories/ZDI-15-628
    Added Reference http://www.zerodayinitiative.com/advisories/ZDI-15-629
    Added Reference https://ics-cert.us-cert.gov/advisories/ICSA-15-335-02
  • CVE Modified by [email protected]

    May. 14, 2024

    Action Type Old Value New Value
  • Modified Analysis by [email protected]

    Dec. 16, 2015

    Action Type Old Value New Value
    Added CPE Configuration Configuration 1 OR *cpe:2.3:a:schneider-electric:proclima:6.1:*:*:*:*:*:*:* (and previous)
    Added CVSS V2 (AV:N/AC:M/Au:N/C:P/I:P/A:P)
    Changed Reference Type http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-329-01 No Types Assigned http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-329-01 Advisory
    Changed Reference Type https://ics-cert.us-cert.gov/advisories/ICSA-15-335-02 US Govt Resource https://ics-cert.us-cert.gov/advisories/ICSA-15-335-02 Advisory, US Govt Resource
    Added CWE CWE-119
  • Initial Analysis by [email protected]

    Dec. 15, 2015

    Action Type Old Value New Value
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days. Following chart shows the EPSS score history of the vulnerability.
Exploit Prediction

EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days.

22.13 }} 6.70%

score

0.96488

percentile

CVSS2 - Vulnerability Scoring System
Access Vector
Access Complexity
Authentication
Confidentiality
Integrity
Availability