An Incorrect Password Management issue was discovered in SMA Solar Technology products. Default passwords exist that are rarely changed. User passwords will almost always be default. Installer passwords are expected to be default or similar across installations installed by the same company (but are sometimes changed). Hidden user accounts have (at least in some cases, though more research is required to test this for all hidden user accounts) a fixed password for all devices; it can never be changed by a user. Other vulnerabilities exist that allow an attacker to get the passwords of these hidden user accounts. NOTE: the vendor reports that it has no influence on the allocation of passwords, and that global hardcoded master passwords do not exist. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
INFO
Published Date :
Aug. 5, 2017, 5:29 p.m.
Last Modified :
Aug. 5, 2024, 6:15 p.m.
Source :
[email protected]
Remotely Exploitable :
Yes !
Impact Score :
5.9
Exploitability Score :
3.9
Affected Products
The following products are affected by CVE-2017-9852
vulnerability.
Even if cvefeed.io
is aware of the exact versions of the
products
that
are
affected, the information is not represented in the table below.
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2017-9852
.
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2017-9852
vulnerability anywhere in the article.
The following table lists the changes that have been made to the
CVE-2017-9852
vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
CVE Modified by [email protected]
Aug. 05, 2024
Action Type Old Value New Value -
CVE Modified by [email protected]
May. 17, 2024
Action Type Old Value New Value -
CVE Modified by [email protected]
May. 14, 2024
Action Type Old Value New Value -
CVE Modified by [email protected]
Apr. 11, 2024
Action Type Old Value New Value -
CVE Modified by [email protected]
Mar. 21, 2024
Action Type Old Value New Value Added Tag MITRE disputed -
CVE Modified by [email protected]
Nov. 07, 2023
Action Type Old Value New Value Changed Description ** DISPUTED ** An Incorrect Password Management issue was discovered in SMA Solar Technology products. Default passwords exist that are rarely changed. User passwords will almost always be default. Installer passwords are expected to be default or similar across installations installed by the same company (but are sometimes changed). Hidden user accounts have (at least in some cases, though more research is required to test this for all hidden user accounts) a fixed password for all devices; it can never be changed by a user. Other vulnerabilities exist that allow an attacker to get the passwords of these hidden user accounts. NOTE: the vendor reports that it has no influence on the allocation of passwords, and that global hardcoded master passwords do not exist. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected. An Incorrect Password Management issue was discovered in SMA Solar Technology products. Default passwords exist that are rarely changed. User passwords will almost always be default. Installer passwords are expected to be default or similar across installations installed by the same company (but are sometimes changed). Hidden user accounts have (at least in some cases, though more research is required to test this for all hidden user accounts) a fixed password for all devices; it can never be changed by a user. Other vulnerabilities exist that allow an attacker to get the passwords of these hidden user accounts. NOTE: the vendor reports that it has no influence on the allocation of passwords, and that global hardcoded master passwords do not exist. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected -
CWE Remap by [email protected]
Oct. 03, 2019
Action Type Old Value New Value Changed CWE CWE-254 CWE-798 -
CVE Modified by [email protected]
Aug. 22, 2017
Action Type Old Value New Value Changed Description An Incorrect Password Management issue was discovered in SMA Solar Technology products. Default passwords exist that are rarely changed. User passwords will almost always be default. Installer passwords are expected to be default or similar across installations installed by the same company (but are sometimes changed). Hidden user accounts have (at least in some cases, though more research is required to test this for all hidden user accounts) a fixed password for all devices; it can never be changed by a user. Other vulnerabilities exist that allow an attacker to get the passwords of these hidden user accounts. ** DISPUTED ** An Incorrect Password Management issue was discovered in SMA Solar Technology products. Default passwords exist that are rarely changed. User passwords will almost always be default. Installer passwords are expected to be default or similar across installations installed by the same company (but are sometimes changed). Hidden user accounts have (at least in some cases, though more research is required to test this for all hidden user accounts) a fixed password for all devices; it can never be changed by a user. Other vulnerabilities exist that allow an attacker to get the passwords of these hidden user accounts. NOTE: the vendor reports that it has no influence on the allocation of passwords, and that global hardcoded master passwords do not exist. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected. Added Reference http://www.sma.de/fileadmin/content/global/specials/documents/cyber-security/Whitepaper-Cyber-Security-AEN1732_07.pdf [No Types Assigned] Added Reference http://www.sma.de/en/statement-on-cyber-security.html [No Types Assigned] -
Initial Analysis by [email protected]
Aug. 15, 2017
Action Type Old Value New Value Added CVSS V2 (AV:N/AC:L/Au:N/C:P/I:N/A:N) Added CVSS V3 AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Changed Reference Type https://horusscenario.com/CVE-information/ No Types Assigned https://horusscenario.com/CVE-information/ Third Party Advisory Added CWE CWE-254 Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_boy_3600_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_boy_3600:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_boy_5000_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_boy_5000:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_tripower_core1_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_tripower_core1:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_tripower_15000tl_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_tripower_15000tl:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_tripower_20000tl_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_tripower_20000tl:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_tripower_25000tl_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_tripower_25000tl:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_tripower_5000tl_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_tripower_5000tl:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_tripower_12000tl_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_tripower_12000tl:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_tripower_60_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_tripower_60:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_boy_3000tl_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_boy_3000tl:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_boy_3600tl_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_boy_3600tl:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_boy_4000tl_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_boy_4000tl:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_boy_5000tl_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_boy_5000tl:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_boy_1.5_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_boy_1.5:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_boy_2.5_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_boy_2.5:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_boy_3.0_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_boy_3.0:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_boy_3.6_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_boy_3.6:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_boy_4.0_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_boy_4.0:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_boy_5.0_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_boy_5.0:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_central_2200_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_central_2200:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_central_1000cp_xt_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_central_1000cp_xt:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_central_800cp_xt_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_central_800cp_xt:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_central_850cp_xt_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_central_850cp_xt:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_central_900cp_xt_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_central_900cp_xt:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_central_500cp_xt_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_central_500cp_xt:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_central_630cp_xt_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_central_630cp_xt:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_central_720cp_xt_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_central_720cp_xt:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_central_760cp_xt_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_central_760cp_xt:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_central_storage_500_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_central_storage_500:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_central_storage_630_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_central_storage_630:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_central_storage_720_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_central_storage_720:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_central_storage_760_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_central_storage_760:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_central_storage_800_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_central_storage_800:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_central_storage_850_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_central_storage_850:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_central_storage_900_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_central_storage_900:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_central_storage_1000_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_central_storage_1000:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_central_storage_2200_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_central_storage_2200:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_central_storage_2500-ev_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_central_storage_2500-ev:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:sma:sunny_boy_storage_2.5_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:sma:sunny_boy_storage_2.5:-:*:*:*:*:*:*:*
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2017-9852
is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2017-9852
weaknesses.
Exploit Prediction
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days.
0.32 }} 0.00%
score
0.65572
percentile