CVE-2018-8872
Schneider Electric Triconex Tricon MP Memory Corruption Vulnerability
Description
In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, system calls read directly from memory addresses within the control program area without any verification. Manipulating this data could allow attacker data to be copied anywhere within memory.
INFO
Published Date :
May 4, 2018, 5:29 p.m.
Last Modified :
Nov. 21, 2024, 4:14 a.m.
Source :
[email protected]
Remotely Exploitable :
Yes !
Impact Score :
5.9
Exploitability Score :
2.2
Affected Products
The following products are affected by CVE-2018-8872
vulnerability.
Even if cvefeed.io
is aware of the exact versions of the
products
that
are
affected, the information is not represented in the table below.
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2018-8872
.
URL | Resource |
---|---|
http://www.securityfocus.com/bid/103947 | Third Party Advisory VDB Entry |
https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02 | Third Party Advisory US Government Resource |
https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/ | Vendor Advisory |
http://www.securityfocus.com/bid/103947 | Third Party Advisory VDB Entry |
https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02 | Third Party Advisory US Government Resource |
https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/ | Vendor Advisory |
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2018-8872
vulnerability anywhere in the article.
The following table lists the changes that have been made to the
CVE-2018-8872
vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
CVE Modified by af854a3a-2127-422b-91ae-364da2661108
Nov. 21, 2024
Action Type Old Value New Value Added Reference http://www.securityfocus.com/bid/103947 Added Reference https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02 Added Reference https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/ -
CVE Modified by [email protected]
May. 14, 2024
Action Type Old Value New Value -
CVE Modified by [email protected]
Oct. 09, 2019
Action Type Old Value New Value Added CWE ICS-CERT CWE-119 -
Reanalysis by [email protected]
Feb. 12, 2019
Action Type Old Value New Value Changed CPE Configuration AND OR *cpe:2.3:o:schneider-electric:triconex_tricon_mp_3008_firmware:*:*:*:*:*:*:*:* versions from (including) 10.0 up to (including) 10.0-10.4 OR cpe:2.3:h:schneider-electric:triconex_tricon_mp_3008:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:schneider-electric:triconex_tricon_mp_3008_firmware:*:*:*:*:*:*:*:* versions from (including) 10.0 up to (including) 10.4 OR cpe:2.3:h:schneider-electric:triconex_tricon_mp_3008:-:*:*:*:*:*:*:* -
Initial Analysis by [email protected]
Jun. 13, 2018
Action Type Old Value New Value Added CVSS V2 (AV:N/AC:M/Au:N/C:C/I:C/A:C) Added CVSS V3 AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H Changed Reference Type https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02 No Types Assigned https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02 Third Party Advisory, US Government Resource Changed Reference Type https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/ No Types Assigned https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/ Vendor Advisory Changed Reference Type http://www.securityfocus.com/bid/103947 No Types Assigned http://www.securityfocus.com/bid/103947 Third Party Advisory, VDB Entry Added CWE CWE-119 Added CPE Configuration AND OR *cpe:2.3:o:schneider-electric:triconex_tricon_mp_3008_firmware:*:*:*:*:*:*:*:* versions from (including) 10.0 up to (including) 10.0-10.4 OR cpe:2.3:h:schneider-electric:triconex_tricon_mp_3008:-:*:*:*:*:*:*:* -
CVE Modified by [email protected]
May. 06, 2018
Action Type Old Value New Value Added Reference http://www.securityfocus.com/bid/103947 [No Types Assigned]
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2018-8872
is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2018-8872
weaknesses.
Exploit Prediction
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days.
0.35 }} -0.03%
score
0.71614
percentile