7.5
HIGH
CVE-2019-10923
Siemens SIMATIC and SINAMICS Devices IRT Denial of Service Vulnerability
Description

An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.

INFO

Published Date :

Oct. 10, 2019, 2:15 p.m.

Last Modified :

Nov. 21, 2024, 4:20 a.m.

Remotely Exploitable :

Yes !

Impact Score :

3.6

Exploitability Score :

3.9
Affected Products

The following products are affected by CVE-2019-10923 vulnerability. Even if cvefeed.io is aware of the exact versions of the products that are affected, the information is not represented in the table below.

ID Vendor Product Action
1 Siemens scalance_x-200irt_firmware
2 Siemens sinumerik_828d_firmware
3 Siemens simatic_winac_rtx_2010_firmware
4 Siemens simatic_winac_rtx_f_2010_firmware
5 Siemens simatic_et_200ecopn_firmware
6 Siemens simatic_et_200m_firmware
7 Siemens simatic_et_200s_firmware
8 Siemens dk_standard_ethernet_controller_firmware
9 Siemens ek-ertec_200p_firmware
10 Siemens sinamics_dcm_firmware
11 Siemens sinamics_dcp_firmware
12 Siemens sinamics_g130_firmware
13 Siemens sinamics_g150_firmware
14 Siemens sinamics_s120_firmware
15 Siemens sinumerik_840d_sl_firmware
16 Siemens simatic_winac_rtx_\(f\)_firmware
17 Siemens sinamics_sl150_firmware
18 Siemens simatic_s7-300_cpu_firmware
19 Siemens simatic_s7-300_cpu
20 Siemens siplus_s7-300_cpu_315-2_pn\/dp_firmware
21 Siemens siplus_s7-300_cpu_317-2_pn\/dp_firmware
22 Siemens simatic_s7-300_cpu_319-3_pn\/dp_firmware
23 Siemens simatic_s7-300_cpu_315-2_pn\/dp_firmware
24 Siemens simatic_s7-300_cpu_317-2_pn\/dp_firmware
25 Siemens ek-ertec_200_firmware
26 Siemens scalance_x-200irt
27 Siemens simatic_s7-300_cpu_312_ifm_firmware
28 Siemens simatic_s7-300_cpu_313_firmware
29 Siemens simatic_s7-300_cpu_314_firmware
30 Siemens simatic_s7-300_cpu_314_ifm_firmware
31 Siemens simatic_s7-300_cpu_315_firmware
32 Siemens simatic_s7-300_cpu_315-2_dp_firmware
33 Siemens simatic_s7-300_cpu_316-2_dp_firmware
34 Siemens simatic_s7-300_cpu_318-2_firmware
35 Siemens sinumerik_840d_sl
36 Siemens sinamics_g120
37 Siemens sinamics_g130
38 Siemens sinamics_g150
39 Siemens sinamics_s110
40 Siemens sinamics_s120
41 Siemens sinamics_s150
42 Siemens sinamics_g110m_firmware
43 Siemens sinamics_s150_firmware
44 Siemens simotion_firmware
45 Siemens sinamics_gh150_firmware
46 Siemens sinamics_gl150_firmware
47 Siemens sinamics_gm150_firmware
48 Siemens sinamics_sm120_firmware
49 Siemens cp1604_firmware
50 Siemens cp1616_firmware
51 Siemens simatic_pn\/pn_coupler_6es7158-3ad01-0xa0_firmware
52 Siemens simatic_s7-400_v6_firmware
53 Siemens simatic_s7-400_pn_v7_firmware
54 Siemens simatic_s7-400_dp_v7_firmware
55 Siemens sinamics_g120_firmware
56 Siemens sinamics_s110_firmware
57 Siemens sinumerik_828d
58 Siemens simatic_et_200mp_im_155-5_pn_hf_firmware
59 Siemens simatic_et_200mp_im_155-5_pn_st_firmware
60 Siemens simatic_et_200sp_im_155-6_pn_hf_firmware
61 Siemens simatic_et_200sp_im_155-6_pn_st_firmware
62 Siemens simatic_et_200ecopn
63 Siemens simatic_et_200m
64 Siemens simatic_et_200s
65 Siemens dk_standard_ethernet_controller
66 Siemens sinamics_dcm
67 Siemens sinamics_dcp
68 Siemens sinamics_g110m
69 Siemens simotion
70 Siemens sinamics_gh150
71 Siemens sinamics_gl150
72 Siemens sinamics_gm150
73 Siemens sinamics_sl150
74 Siemens sinamics_sm120
75 Siemens ek-ertec_200p
76 Siemens ek-ertec_200
77 Siemens simatic_s7-300_cpu_312_ifm
78 Siemens simatic_s7-300_cpu_313
79 Siemens simatic_s7-300_cpu_314
80 Siemens simatic_s7-300_cpu_314_ifm
81 Siemens simatic_s7-300_cpu_315
82 Siemens simatic_s7-300_cpu_315-2_dp
83 Siemens simatic_s7-300_cpu_316-2_dp
84 Siemens simatic_s7-300_cpu_318-2
85 Siemens simatic_s7-400_pn_v7
86 Siemens simatic_s7-400_dp_v7
87 Siemens simatic_s7-400_v6
88 Siemens cp1604
89 Siemens cp1616
90 Siemens simatic_pn\/pn_coupler_6es7158-3ad01-0xa0
91 Siemens simatic_winac_rtx_\(f\)
References to Advisories, Solutions, and Tools

Here, you will find a curated list of external links that provide in-depth information, practical solutions, and valuable tools related to CVE-2019-10923.

URL Resource
https://cert-portal.siemens.com/productcert/html/ssa-349422.html
https://cert-portal.siemens.com/productcert/pdf/ssa-349422.pdf Vendor Advisory
https://cert-portal.siemens.com/productcert/pdf/ssa-349422.pdf Vendor Advisory

We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).

Results are limited to the first 15 repositories due to potential performance issues.

The following list is the news that have been mention CVE-2019-10923 vulnerability anywhere in the article.

The following table lists the changes that have been made to the CVE-2019-10923 vulnerability over time.

Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.

  • CVE Modified by af854a3a-2127-422b-91ae-364da2661108

    Nov. 21, 2024

    Action Type Old Value New Value
    Added Reference https://cert-portal.siemens.com/productcert/pdf/ssa-349422.pdf
  • CVE Modified by [email protected]

    Sep. 10, 2024

    Action Type Old Value New Value
    Changed Description A vulnerability has been identified in SIMATIC S7-400 CPU 414-3 PN/DP V7, SIMATIC S7-400 CPU 414F-3 PN/DP V7, SIMATIC S7-400 CPU 416-3 PN/DP V7, SIMATIC S7-400 CPU 416F-3 PN/DP V7, Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SCALANCE X-200IRT switch family (incl. SIPLUS NET variants), SIMATIC ET 200pro IM154-8 PN/DP CPU, SIMATIC ET 200pro IM154-8F PN/DP CPU, SIMATIC ET 200pro IM154-8FX PN/DP CPU, SIMATIC ET 200S IM151-8 PN/DP CPU, SIMATIC ET 200S IM151-8F PN/DP CPU, SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200pro, SIMATIC ET200S (incl. SIPLUS variants), SIMATIC NET CP 1604, SIMATIC NET CP 1616, SIMATIC PN/PN Coupler (incl. SIPLUS NET variants), SIMATIC S7-300 CPU 314C-2 PN/DP, SIMATIC S7-300 CPU 315-2 PN/DP, SIMATIC S7-300 CPU 315F-2 PN/DP, SIMATIC S7-300 CPU 315T-3 PN/DP, SIMATIC S7-300 CPU 317-2 PN/DP, SIMATIC S7-300 CPU 317F-2 PN/DP, SIMATIC S7-300 CPU 317T-3 PN/DP, SIMATIC S7-300 CPU 317TF-3 PN/DP, SIMATIC S7-300 CPU 319-3 PN/DP, SIMATIC S7-300 CPU 319F-3 PN/DP, SIMATIC S7-400 CPU 412-2 PN V7, SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants), SIMATIC WinAC RTX 2010, SIMATIC WinAC RTX F 2010, SIMOTION, SINAMICS DCM, SINAMICS DCP, SINAMICS G110M V4.7 Control Unit, SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants), SINAMICS G130 V4.7 Control Unit, SINAMICS G150 Control Unit, SINAMICS GH150 V4.7 Control Unit, SINAMICS GL150 V4.7 Control Unit, SINAMICS GM150 V4.7 Control Unit, SINAMICS S110 Control Unit, SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants), SINAMICS S150 Control Unit, SINAMICS SL150 V4.7 Control Unit, SINAMICS SM120 V4.7 Control Unit, SINUMERIK 828D, SINUMERIK 840D sl, SIPLUS ET 200S IM151-8 PN/DP CPU, SIPLUS ET 200S IM151-8F PN/DP CPU, SIPLUS S7-300 CPU 314C-2 PN/DP, SIPLUS S7-300 CPU 315-2 PN/DP, SIPLUS S7-300 CPU 315F-2 PN/DP, SIPLUS S7-300 CPU 317-2 PN/DP, SIPLUS S7-300 CPU 317F-2 PN/DP, SIPLUS S7-400 CPU 414-3 PN/DP V7, SIPLUS S7-400 CPU 416-3 PN/DP V7. An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation. An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.
    Added Reference Siemens AG https://cert-portal.siemens.com/productcert/html/ssa-349422.html [No types assigned]
  • CVE Modified by [email protected]

    May. 14, 2024

    Action Type Old Value New Value
  • CVE Modified by [email protected]

    May. 09, 2023

    Action Type Old Value New Value
    Changed Description A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7, SIMATIC S7-400 CPU 412-2 DP V7, SIMATIC S7-400 CPU 412-2 PN/DP V7, SIMATIC S7-400 CPU 414-2 DP V7, SIMATIC S7-400 CPU 414-3 DP V7, SIMATIC S7-400 CPU 414-3 PN/DP V7, SIMATIC S7-400 CPU 414F-3 PN/DP V7, SIMATIC S7-400 CPU 416-2 DP V7, SIMATIC S7-400 CPU 416-3 DP V7, SIMATIC S7-400 CPU 416-3 PN/DP V7, SIMATIC S7-400 CPU 416F-2 DP V7, SIMATIC S7-400 CPU 416F-3 PN/DP V7, SIMATIC S7-400 CPU 417-4 DP V7, Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SCALANCE X-200IRT switch family (incl. SIPLUS NET variants), SIMATIC ET 200pro IM154-8 PN/DP CPU, SIMATIC ET 200pro IM154-8F PN/DP CPU, SIMATIC ET 200pro IM154-8FX PN/DP CPU, SIMATIC ET 200S IM151-8 PN/DP CPU, SIMATIC ET 200S IM151-8F PN/DP CPU, SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200pro, SIMATIC ET200S (incl. SIPLUS variants), SIMATIC NET CP 1604, SIMATIC NET CP 1616, SIMATIC PN/PN Coupler (incl. SIPLUS NET variants), SIMATIC S7-300 CPU 314C-2 PN/DP, SIMATIC S7-300 CPU 315-2 PN/DP, SIMATIC S7-300 CPU 315F-2 PN/DP, SIMATIC S7-300 CPU 315T-3 PN/DP, SIMATIC S7-300 CPU 317-2 PN/DP, SIMATIC S7-300 CPU 317F-2 PN/DP, SIMATIC S7-300 CPU 317T-3 PN/DP, SIMATIC S7-300 CPU 317TF-3 PN/DP, SIMATIC S7-300 CPU 319-3 PN/DP, SIMATIC S7-300 CPU 319F-3 PN/DP, SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants), SIMATIC WinAC RTX 2010, SIMATIC WinAC RTX F 2010, SIMOTION, SINAMICS DCM, SINAMICS DCP, SINAMICS G110M V4.7 Control Unit, SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants), SINAMICS G130 V4.7 Control Unit, SINAMICS G150 Control Unit, SINAMICS GH150 V4.7 Control Unit, SINAMICS GL150 V4.7 Control Unit, SINAMICS GM150 V4.7 Control Unit, SINAMICS S110 Control Unit, SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants), SINAMICS S150 Control Unit, SINAMICS SL150 V4.7 Control Unit, SINAMICS SM120 V4.7 Control Unit, SINUMERIK 828D, SINUMERIK 840D sl, SIPLUS ET 200S IM151-8 PN/DP CPU, SIPLUS ET 200S IM151-8F PN/DP CPU, SIPLUS S7-300 CPU 314C-2 PN/DP, SIPLUS S7-300 CPU 315-2 PN/DP, SIPLUS S7-300 CPU 315F-2 PN/DP, SIPLUS S7-300 CPU 317-2 PN/DP, SIPLUS S7-300 CPU 317F-2 PN/DP, SIPLUS S7-400 CPU 414-3 PN/DP V7, SIPLUS S7-400 CPU 416-3 PN/DP V7, SIPLUS S7-400 CPU 416-3 V7, SIPLUS S7-400 CPU 417-4 V7. An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation. A vulnerability has been identified in SIMATIC S7-400 CPU 414-3 PN/DP V7, SIMATIC S7-400 CPU 414F-3 PN/DP V7, SIMATIC S7-400 CPU 416-3 PN/DP V7, SIMATIC S7-400 CPU 416F-3 PN/DP V7, Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SCALANCE X-200IRT switch family (incl. SIPLUS NET variants), SIMATIC ET 200pro IM154-8 PN/DP CPU, SIMATIC ET 200pro IM154-8F PN/DP CPU, SIMATIC ET 200pro IM154-8FX PN/DP CPU, SIMATIC ET 200S IM151-8 PN/DP CPU, SIMATIC ET 200S IM151-8F PN/DP CPU, SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200pro, SIMATIC ET200S (incl. SIPLUS variants), SIMATIC NET CP 1604, SIMATIC NET CP 1616, SIMATIC PN/PN Coupler (incl. SIPLUS NET variants), SIMATIC S7-300 CPU 314C-2 PN/DP, SIMATIC S7-300 CPU 315-2 PN/DP, SIMATIC S7-300 CPU 315F-2 PN/DP, SIMATIC S7-300 CPU 315T-3 PN/DP, SIMATIC S7-300 CPU 317-2 PN/DP, SIMATIC S7-300 CPU 317F-2 PN/DP, SIMATIC S7-300 CPU 317T-3 PN/DP, SIMATIC S7-300 CPU 317TF-3 PN/DP, SIMATIC S7-300 CPU 319-3 PN/DP, SIMATIC S7-300 CPU 319F-3 PN/DP, SIMATIC S7-400 CPU 412-2 PN V7, SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants), SIMATIC WinAC RTX 2010, SIMATIC WinAC RTX F 2010, SIMOTION, SINAMICS DCM, SINAMICS DCP, SINAMICS G110M V4.7 Control Unit, SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants), SINAMICS G130 V4.7 Control Unit, SINAMICS G150 Control Unit, SINAMICS GH150 V4.7 Control Unit, SINAMICS GL150 V4.7 Control Unit, SINAMICS GM150 V4.7 Control Unit, SINAMICS S110 Control Unit, SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants), SINAMICS S150 Control Unit, SINAMICS SL150 V4.7 Control Unit, SINAMICS SM120 V4.7 Control Unit, SINUMERIK 828D, SINUMERIK 840D sl, SIPLUS ET 200S IM151-8 PN/DP CPU, SIPLUS ET 200S IM151-8F PN/DP CPU, SIPLUS S7-300 CPU 314C-2 PN/DP, SIPLUS S7-300 CPU 315-2 PN/DP, SIPLUS S7-300 CPU 315F-2 PN/DP, SIPLUS S7-300 CPU 317-2 PN/DP, SIPLUS S7-300 CPU 317F-2 PN/DP, SIPLUS S7-400 CPU 414-3 PN/DP V7, SIPLUS S7-400 CPU 416-3 PN/DP V7. An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.
  • CVE Modified by [email protected]

    Apr. 11, 2023

    Action Type Old Value New Value
    Changed Description A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SCALANCE X-200IRT switch family (incl. SIPLUS NET variants), SIMATIC ET 200pro IM154-8 PN/DP CPU, SIMATIC ET 200pro IM154-8F PN/DP CPU, SIMATIC ET 200pro IM154-8FX PN/DP CPU, SIMATIC ET 200S IM151-8 PN/DP CPU, SIMATIC ET 200S IM151-8F PN/DP CPU, SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200pro, SIMATIC ET200S (incl. SIPLUS variants), SIMATIC NET CP 1604, SIMATIC NET CP 1616, SIMATIC PN/PN Coupler (incl. SIPLUS NET variants), SIMATIC S7-300 CPU 314C-2 PN/DP, SIMATIC S7-300 CPU 315-2 PN/DP, SIMATIC S7-300 CPU 315F-2 PN/DP, SIMATIC S7-300 CPU 315T-3 PN/DP, SIMATIC S7-300 CPU 317-2 PN/DP, SIMATIC S7-300 CPU 317F-2 PN/DP, SIMATIC S7-300 CPU 317T-3 PN/DP, SIMATIC S7-300 CPU 317TF-3 PN/DP, SIMATIC S7-300 CPU 319-3 PN/DP, SIMATIC S7-300 CPU 319F-3 PN/DP, SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), SIMATIC WinAC RTX 2010, SIMATIC WinAC RTX F 2010, SIMOTION (incl. SIPLUS variants), SINAMICS DCM, SINAMICS DCP, SINAMICS G110M V4.7 Control Unit, SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants), SINAMICS G130 V4.7 Control Unit, SINAMICS G150 Control Unit, SINAMICS GH150 V4.7 Control Unit, SINAMICS GL150 V4.7 Control Unit, SINAMICS GM150 V4.7 Control Unit, SINAMICS S110 Control Unit, SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants), SINAMICS S150 Control Unit, SINAMICS SL150 V4.7 Control Unit, SINAMICS SM120 V4.7 Control Unit, SINUMERIK 828D, SINUMERIK 840D sl, SIPLUS ET 200S IM151-8 PN/DP CPU, SIPLUS ET 200S IM151-8F PN/DP CPU, SIPLUS S7-300 CPU 314C-2 PN/DP, SIPLUS S7-300 CPU 315-2 PN/DP, SIPLUS S7-300 CPU 315F-2 PN/DP, SIPLUS S7-300 CPU 317-2 PN/DP, SIPLUS S7-300 CPU 317F-2 PN/DP. An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation. A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7, SIMATIC S7-400 CPU 412-2 DP V7, SIMATIC S7-400 CPU 412-2 PN/DP V7, SIMATIC S7-400 CPU 414-2 DP V7, SIMATIC S7-400 CPU 414-3 DP V7, SIMATIC S7-400 CPU 414-3 PN/DP V7, SIMATIC S7-400 CPU 414F-3 PN/DP V7, SIMATIC S7-400 CPU 416-2 DP V7, SIMATIC S7-400 CPU 416-3 DP V7, SIMATIC S7-400 CPU 416-3 PN/DP V7, SIMATIC S7-400 CPU 416F-2 DP V7, SIMATIC S7-400 CPU 416F-3 PN/DP V7, SIMATIC S7-400 CPU 417-4 DP V7, Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SCALANCE X-200IRT switch family (incl. SIPLUS NET variants), SIMATIC ET 200pro IM154-8 PN/DP CPU, SIMATIC ET 200pro IM154-8F PN/DP CPU, SIMATIC ET 200pro IM154-8FX PN/DP CPU, SIMATIC ET 200S IM151-8 PN/DP CPU, SIMATIC ET 200S IM151-8F PN/DP CPU, SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200pro, SIMATIC ET200S (incl. SIPLUS variants), SIMATIC NET CP 1604, SIMATIC NET CP 1616, SIMATIC PN/PN Coupler (incl. SIPLUS NET variants), SIMATIC S7-300 CPU 314C-2 PN/DP, SIMATIC S7-300 CPU 315-2 PN/DP, SIMATIC S7-300 CPU 315F-2 PN/DP, SIMATIC S7-300 CPU 315T-3 PN/DP, SIMATIC S7-300 CPU 317-2 PN/DP, SIMATIC S7-300 CPU 317F-2 PN/DP, SIMATIC S7-300 CPU 317T-3 PN/DP, SIMATIC S7-300 CPU 317TF-3 PN/DP, SIMATIC S7-300 CPU 319-3 PN/DP, SIMATIC S7-300 CPU 319F-3 PN/DP, SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants), SIMATIC WinAC RTX 2010, SIMATIC WinAC RTX F 2010, SIMOTION, SINAMICS DCM, SINAMICS DCP, SINAMICS G110M V4.7 Control Unit, SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants), SINAMICS G130 V4.7 Control Unit, SINAMICS G150 Control Unit, SINAMICS GH150 V4.7 Control Unit, SINAMICS GL150 V4.7 Control Unit, SINAMICS GM150 V4.7 Control Unit, SINAMICS S110 Control Unit, SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants), SINAMICS S150 Control Unit, SINAMICS SL150 V4.7 Control Unit, SINAMICS SM120 V4.7 Control Unit, SINUMERIK 828D, SINUMERIK 840D sl, SIPLUS ET 200S IM151-8 PN/DP CPU, SIPLUS ET 200S IM151-8F PN/DP CPU, SIPLUS S7-300 CPU 314C-2 PN/DP, SIPLUS S7-300 CPU 315-2 PN/DP, SIPLUS S7-300 CPU 315F-2 PN/DP, SIPLUS S7-300 CPU 317-2 PN/DP, SIPLUS S7-300 CPU 317F-2 PN/DP, SIPLUS S7-400 CPU 414-3 PN/DP V7, SIPLUS S7-400 CPU 416-3 PN/DP V7, SIPLUS S7-400 CPU 416-3 V7, SIPLUS S7-400 CPU 417-4 V7. An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.
  • CVE Modified by [email protected]

    Jan. 10, 2023

    Action Type Old Value New Value
    Changed Description A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions < V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions < V4.5.0 Patch 01), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions < V4.5.0), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.2.1), SIMATIC ET200M (incl. SIPLUS variants) (All versions), SIMATIC ET200S (incl. SIPLUS variants) (All versions), SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 (All versions), SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 (All versions), SIMATIC ET200ecoPN, 4AO U/I 4xM12 (All versions), SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 (All versions), SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 (All versions), SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 (All versions), SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 (All versions), SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 (All versions), SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 (All versions), SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 (All versions), SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 (All versions), SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 (All versions), SIMATIC ET200ecoPN: IO-Link Master (All versions), SIMATIC ET200pro (All versions), SIMATIC NET CP 1604 (All versions < V2.8), SIMATIC NET CP 1616 (All versions < V2.8), SIMATIC PN/PN Coupler 6ES7158-3AD01-0XA0 (incl. SIPLUS NET variant) (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions < SIMATIC WinAC RTX 2010 SP3), SIMOTION (incl. SIPLUS variants) (All versions), SINAMICS DCM (All versions < V1.5 HF1), SINAMICS DCP (All versions < V1.3), SINAMICS G110M V4.7 Control Unit (All versions < V4.7 SP10 HF5), SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants) (All versions < V4.7 SP10 HF5), SINAMICS G130 V4.7 Control Unit (All versions < V4.7 HF29), SINAMICS G150 Control Unit (All versions < V4.8), SINAMICS GH150 V4.7 Control Unit (All versions), SINAMICS GL150 V4.7 Control Unit (All versions), SINAMICS GM150 V4.7 Control Unit (All versions), SINAMICS S110 Control Unit (All versions), SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants) (All versions < V4.7 HF34), SINAMICS S150 Control Unit (All versions < V4.8), SINAMICS SL150 V4.7 Control Unit (All versions < V4.7 HF33), SINAMICS SM120 V4.7 Control Unit (All versions), SINUMERIK 828D (All versions < V4.8 SP5), SINUMERIK 840D sl (All versions). An attacker with network access to an affected product may cause a Denial-of-Service condition by breaking the real-time synchronization (IRT) of the affected installation. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts the availability of the affected installations. A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SCALANCE X-200IRT switch family (incl. SIPLUS NET variants), SIMATIC ET 200pro IM154-8 PN/DP CPU, SIMATIC ET 200pro IM154-8F PN/DP CPU, SIMATIC ET 200pro IM154-8FX PN/DP CPU, SIMATIC ET 200S IM151-8 PN/DP CPU, SIMATIC ET 200S IM151-8F PN/DP CPU, SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200pro, SIMATIC ET200S (incl. SIPLUS variants), SIMATIC NET CP 1604, SIMATIC NET CP 1616, SIMATIC PN/PN Coupler (incl. SIPLUS NET variants), SIMATIC S7-300 CPU 314C-2 PN/DP, SIMATIC S7-300 CPU 315-2 PN/DP, SIMATIC S7-300 CPU 315F-2 PN/DP, SIMATIC S7-300 CPU 315T-3 PN/DP, SIMATIC S7-300 CPU 317-2 PN/DP, SIMATIC S7-300 CPU 317F-2 PN/DP, SIMATIC S7-300 CPU 317T-3 PN/DP, SIMATIC S7-300 CPU 317TF-3 PN/DP, SIMATIC S7-300 CPU 319-3 PN/DP, SIMATIC S7-300 CPU 319F-3 PN/DP, SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), SIMATIC WinAC RTX 2010, SIMATIC WinAC RTX F 2010, SIMOTION (incl. SIPLUS variants), SINAMICS DCM, SINAMICS DCP, SINAMICS G110M V4.7 Control Unit, SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants), SINAMICS G130 V4.7 Control Unit, SINAMICS G150 Control Unit, SINAMICS GH150 V4.7 Control Unit, SINAMICS GL150 V4.7 Control Unit, SINAMICS GM150 V4.7 Control Unit, SINAMICS S110 Control Unit, SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants), SINAMICS S150 Control Unit, SINAMICS SL150 V4.7 Control Unit, SINAMICS SM120 V4.7 Control Unit, SINUMERIK 828D, SINUMERIK 840D sl, SIPLUS ET 200S IM151-8 PN/DP CPU, SIPLUS ET 200S IM151-8F PN/DP CPU, SIPLUS S7-300 CPU 314C-2 PN/DP, SIPLUS S7-300 CPU 315-2 PN/DP, SIPLUS S7-300 CPU 315F-2 PN/DP, SIPLUS S7-300 CPU 317-2 PN/DP, SIPLUS S7-300 CPU 317F-2 PN/DP. An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.
    Added CVSS V3.1 Siemens AG AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
  • CVE Modified by [email protected]

    Feb. 09, 2022

    Action Type Old Value New Value
    Changed Description A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions < V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions < V4.5.0 Patch 01), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions < V4.5.0), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.2.1), SIMATIC ET200M (incl. SIPLUS variants) (All versions), SIMATIC ET200S (incl. SIPLUS variants) (All versions), SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 (6ES7141-6BH00-0AB0) (All versions), SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 (6ES7142-6BH00-0AB0) (All versions), SIMATIC ET200ecoPN, 4AO U/I 4xM12 (6ES7145-6HD00-0AB0) (All versions), SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 (6ES7147-6BG00-0AB0) (All versions), SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 (6ES7142-6BR00-0AB0) (All versions), SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 (6ES7144-6KD50-0AB0) (All versions), SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 (6ES7144-6KD00-0AB0) (All versions), SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 (6ES7141-6BF00-0AB0) (All versions), SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 (6ES7141-6BG00-0AB0) (All versions), SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 (6ES7142-6BF50-0AB0) (All versions), SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 (6ES7142-6BF00-0AB0) (All versions), SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 (6ES7142-6BG00-0AB0) (All versions), SIMATIC ET200ecoPN: IO-Link Master (6ES7148-6JA00-0AB0) (All versions), SIMATIC ET200pro (All versions), SIMATIC NET CP 1604 (All versions < V2.8), SIMATIC NET CP 1616 (All versions < V2.8), SIMATIC PN/PN Coupler 6ES7158-3AD01-0XA0 (incl. SIPLUS NET variant) (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions < SIMATIC WinAC RTX 2010 SP3), SIMOTION (incl. SIPLUS variants) (All versions), SINAMICS DCM (All versions < V1.5 HF1), SINAMICS DCP (All versions < V1.3), SINAMICS G110M V4.7 Control Unit (All versions < V4.7 SP10 HF5), SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants) (All versions < V4.7 SP10 HF5), SINAMICS G130 V4.7 Control Unit (All versions < V4.7 HF29), SINAMICS G150 Control Unit (All versions < V4.8), SINAMICS GH150 V4.7 Control Unit (All versions), SINAMICS GL150 V4.7 Control Unit (All versions), SINAMICS GM150 V4.7 Control Unit (All versions), SINAMICS S110 Control Unit (All versions), SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants) (All versions < V4.7 HF34), SINAMICS S150 Control Unit (All versions < V4.8), SINAMICS SL150 V4.7 Control Unit (All versions < V4.7 HF33), SINAMICS SM120 V4.7 Control Unit (All versions), SINUMERIK 828D (All versions < V4.8 SP5), SINUMERIK 840D sl (All versions). An attacker with network access to an affected product may cause a Denial-of-Service condition by breaking the real-time synchronization (IRT) of the affected installation. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts the availability of the affected installations. A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions < V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions < V4.5.0 Patch 01), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions < V4.5.0), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.2.1), SIMATIC ET200M (incl. SIPLUS variants) (All versions), SIMATIC ET200S (incl. SIPLUS variants) (All versions), SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 (All versions), SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 (All versions), SIMATIC ET200ecoPN, 4AO U/I 4xM12 (All versions), SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 (All versions), SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 (All versions), SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 (All versions), SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 (All versions), SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 (All versions), SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 (All versions), SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 (All versions), SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 (All versions), SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 (All versions), SIMATIC ET200ecoPN: IO-Link Master (All versions), SIMATIC ET200pro (All versions), SIMATIC NET CP 1604 (All versions < V2.8), SIMATIC NET CP 1616 (All versions < V2.8), SIMATIC PN/PN Coupler 6ES7158-3AD01-0XA0 (incl. SIPLUS NET variant) (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions < SIMATIC WinAC RTX 2010 SP3), SIMOTION (incl. SIPLUS variants) (All versions), SINAMICS DCM (All versions < V1.5 HF1), SINAMICS DCP (All versions < V1.3), SINAMICS G110M V4.7 Control Unit (All versions < V4.7 SP10 HF5), SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants) (All versions < V4.7 SP10 HF5), SINAMICS G130 V4.7 Control Unit (All versions < V4.7 HF29), SINAMICS G150 Control Unit (All versions < V4.8), SINAMICS GH150 V4.7 Control Unit (All versions), SINAMICS GL150 V4.7 Control Unit (All versions), SINAMICS GM150 V4.7 Control Unit (All versions), SINAMICS S110 Control Unit (All versions), SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants) (All versions < V4.7 HF34), SINAMICS S150 Control Unit (All versions < V4.8), SINAMICS SL150 V4.7 Control Unit (All versions < V4.7 HF33), SINAMICS SM120 V4.7 Control Unit (All versions), SINUMERIK 828D (All versions < V4.8 SP5), SINUMERIK 840D sl (All versions). An attacker with network access to an affected product may cause a Denial-of-Service condition by breaking the real-time synchronization (IRT) of the affected installation. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts the availability of the affected installations.
  • CVE Modified by [email protected]

    Oct. 12, 2021

    Action Type Old Value New Value
    Changed Description A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions < V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions < V4.5.0 Patch 01), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions < V4.5.0), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.2.1), SIMATIC ET200M (incl. SIPLUS variants) (All versions), SIMATIC ET200S (incl. SIPLUS variants) (All versions), SIMATIC ET200ecoPN (except 6ES7141-6BG00-0BB0, 6ES7141-6BH00-0BB0, 6ES7142-6BG00-0BB0, 6ES7142-6BR00-0BB0, 6ES7143-6BH00-0BB0, 6ES7146-6FF00-0AB0 and 6ES7148-6JD00-0AB0) (All versions), SIMATIC ET200ecoPN (except 6ES7141-6BG00-0BB0, 6ES7141-6BH00-0BB0, 6ES7142-6BG00-0BB0, 6ES7142-6BR00-0BB0, 6S7143-6BH00-0BB0, 6ES7146-6FF00-0AB0, 6ES7148-6JD00-0AB0 and 6ES7148-6JG00-0BB0) (All versions), SIMATIC ET200pro (All versions), SIMATIC NET CP 1604 (All versions < V2.8), SIMATIC NET CP 1616 (All versions < V2.8), SIMATIC PN/PN Coupler 6ES7158-3AD01-0XA0 (incl. SIPLUS NET variant) (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions < SIMATIC WinAC RTX 2010 SP3), SIMOTION (incl. SIPLUS variants) (All versions), SINAMICS DCM (All versions < V1.5 HF1), SINAMICS DCP (All versions < V1.3), SINAMICS G110M V4.7 Control Unit (All versions < V4.7 SP10 HF5), SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants) (All versions < V4.7 SP10 HF5), SINAMICS G130 V4.7 Control Unit (All versions < V4.7 HF29), SINAMICS G150 Control Unit (All versions < V4.8), SINAMICS GH150 V4.7 Control Unit (All versions), SINAMICS GL150 V4.7 Control Unit (All versions), SINAMICS GM150 V4.7 Control Unit (All versions), SINAMICS S110 Control Unit (All versions), SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants) (All versions < V4.7 HF34), SINAMICS S150 Control Unit (All versions < V4.8), SINAMICS SL150 V4.7 Control Unit (All versions < V4.7 HF33), SINAMICS SM120 V4.7 Control Unit (All versions), SINUMERIK 828D (All versions < V4.8 SP5), SINUMERIK 840D sl (All versions). An attacker with network access to an affected product may cause a Denial-of-Service condition by breaking the real-time synchronization (IRT) of the affected installation. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts the availability of the affected installations. A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions < V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions < V4.5.0 Patch 01), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions < V4.5.0), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.2.1), SIMATIC ET200M (incl. SIPLUS variants) (All versions), SIMATIC ET200S (incl. SIPLUS variants) (All versions), SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 (6ES7141-6BH00-0AB0) (All versions), SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 (6ES7142-6BH00-0AB0) (All versions), SIMATIC ET200ecoPN, 4AO U/I 4xM12 (6ES7145-6HD00-0AB0) (All versions), SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 (6ES7147-6BG00-0AB0) (All versions), SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 (6ES7142-6BR00-0AB0) (All versions), SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 (6ES7144-6KD50-0AB0) (All versions), SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 (6ES7144-6KD00-0AB0) (All versions), SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 (6ES7141-6BF00-0AB0) (All versions), SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 (6ES7141-6BG00-0AB0) (All versions), SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 (6ES7142-6BF50-0AB0) (All versions), SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 (6ES7142-6BF00-0AB0) (All versions), SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 (6ES7142-6BG00-0AB0) (All versions), SIMATIC ET200ecoPN: IO-Link Master (6ES7148-6JA00-0AB0) (All versions), SIMATIC ET200pro (All versions), SIMATIC NET CP 1604 (All versions < V2.8), SIMATIC NET CP 1616 (All versions < V2.8), SIMATIC PN/PN Coupler 6ES7158-3AD01-0XA0 (incl. SIPLUS NET variant) (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions < SIMATIC WinAC RTX 2010 SP3), SIMOTION (incl. SIPLUS variants) (All versions), SINAMICS DCM (All versions < V1.5 HF1), SINAMICS DCP (All versions < V1.3), SINAMICS G110M V4.7 Control Unit (All versions < V4.7 SP10 HF5), SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants) (All versions < V4.7 SP10 HF5), SINAMICS G130 V4.7 Control Unit (All versions < V4.7 HF29), SINAMICS G150 Control Unit (All versions < V4.8), SINAMICS GH150 V4.7 Control Unit (All versions), SINAMICS GL150 V4.7 Control Unit (All versions), SINAMICS GM150 V4.7 Control Unit (All versions), SINAMICS S110 Control Unit (All versions), SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants) (All versions < V4.7 HF34), SINAMICS S150 Control Unit (All versions < V4.8), SINAMICS SL150 V4.7 Control Unit (All versions < V4.7 HF33), SINAMICS SM120 V4.7 Control Unit (All versions), SINUMERIK 828D (All versions < V4.8 SP5), SINUMERIK 840D sl (All versions). An attacker with network access to an affected product may cause a Denial-of-Service condition by breaking the real-time synchronization (IRT) of the affected installation. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts the availability of the affected installations.
  • CVE Modified by [email protected]

    Feb. 09, 2021

    Action Type Old Value New Value
    Changed Description A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions < V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions < V4.5.0 Patch 01), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions < V4.5.0), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.2.1), SIMATIC ET200M (incl. SIPLUS variants) (All versions), SIMATIC ET200S (incl. SIPLUS variants) (All versions), SIMATIC ET200ecoPN (except 6ES7141-6BG00-0BB0, 6ES7141-6BH00-0BB0, 6ES7142-6BG00-0BB0, 6ES7142-6BR00-0BB0, 6ES7143-6BH00-0BB0, 6ES7146-6FF00-0AB0 and 6ES7148-6JD00-0AB0) (All versions), SIMATIC ET200pro (All versions), SIMATIC NET CP 1604 (All versions < V2.8), SIMATIC NET CP 1616 (All versions < V2.8), SIMATIC PN/PN Coupler 6ES7158-3AD01-0XA0 (incl. SIPLUS NET variant) (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions < SIMATIC WinAC RTX 2010 SP3), SIMOTION (incl. SIPLUS variants) (All versions), SINAMICS DCM (All versions < V1.5 HF1), SINAMICS DCP (All versions < V1.3), SINAMICS G110M V4.7 Control Unit (All versions < V4.7 SP10 HF5), SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants) (All versions < V4.7 SP10 HF5), SINAMICS G130 V4.7 Control Unit (All versions < V4.7 HF29), SINAMICS G150 Control Unit (All versions < V4.8), SINAMICS GH150 V4.7 Control Unit (All versions), SINAMICS GL150 V4.7 Control Unit (All versions), SINAMICS GM150 V4.7 Control Unit (All versions), SINAMICS S110 Control Unit (All versions), SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants) (All versions < V4.7 HF34), SINAMICS S150 Control Unit (All versions < V4.8), SINAMICS SL150 V4.7 Control Unit (All versions < V4.7 HF33), SINAMICS SM120 V4.7 Control Unit (All versions), SINUMERIK 828D (All versions < V4.8 SP5), SINUMERIK 840D sl (All versions). An attacker with network access to an affected product may cause a Denial-of-Service condition by breaking the real-time synchronization (IRT) of the affected installation. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts the availability of the affected installations. A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions < V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions < V4.5.0 Patch 01), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions < V4.5.0), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.2.1), SIMATIC ET200M (incl. SIPLUS variants) (All versions), SIMATIC ET200S (incl. SIPLUS variants) (All versions), SIMATIC ET200ecoPN (except 6ES7141-6BG00-0BB0, 6ES7141-6BH00-0BB0, 6ES7142-6BG00-0BB0, 6ES7142-6BR00-0BB0, 6ES7143-6BH00-0BB0, 6ES7146-6FF00-0AB0 and 6ES7148-6JD00-0AB0) (All versions), SIMATIC ET200ecoPN (except 6ES7141-6BG00-0BB0, 6ES7141-6BH00-0BB0, 6ES7142-6BG00-0BB0, 6ES7142-6BR00-0BB0, 6S7143-6BH00-0BB0, 6ES7146-6FF00-0AB0, 6ES7148-6JD00-0AB0 and 6ES7148-6JG00-0BB0) (All versions), SIMATIC ET200pro (All versions), SIMATIC NET CP 1604 (All versions < V2.8), SIMATIC NET CP 1616 (All versions < V2.8), SIMATIC PN/PN Coupler 6ES7158-3AD01-0XA0 (incl. SIPLUS NET variant) (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions < SIMATIC WinAC RTX 2010 SP3), SIMOTION (incl. SIPLUS variants) (All versions), SINAMICS DCM (All versions < V1.5 HF1), SINAMICS DCP (All versions < V1.3), SINAMICS G110M V4.7 Control Unit (All versions < V4.7 SP10 HF5), SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants) (All versions < V4.7 SP10 HF5), SINAMICS G130 V4.7 Control Unit (All versions < V4.7 HF29), SINAMICS G150 Control Unit (All versions < V4.8), SINAMICS GH150 V4.7 Control Unit (All versions), SINAMICS GL150 V4.7 Control Unit (All versions), SINAMICS GM150 V4.7 Control Unit (All versions), SINAMICS S110 Control Unit (All versions), SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants) (All versions < V4.7 HF34), SINAMICS S150 Control Unit (All versions < V4.8), SINAMICS SL150 V4.7 Control Unit (All versions < V4.7 HF33), SINAMICS SM120 V4.7 Control Unit (All versions), SINUMERIK 828D (All versions < V4.8 SP5), SINUMERIK 840D sl (All versions). An attacker with network access to an affected product may cause a Denial-of-Service condition by breaking the real-time synchronization (IRT) of the affected installation. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts the availability of the affected installations.
  • Modified Analysis by [email protected]

    Sep. 29, 2020

    Action Type Old Value New Value
    Changed CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-300_cpu:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.3.17 OR cpe:2.3:h:siemens:simatic_s7-300_cpu:-:*:*:*:*:*:*:*
    Changed CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-300_cpu_312_ifm_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-300_cpu_312_ifm:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:siemens:simatic_s7-300_cpu_312_ifm_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.3.17 OR cpe:2.3:h:siemens:simatic_s7-300_cpu_312_ifm:-:*:*:*:*:*:*:*
    Changed CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-300_cpu_313_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-300_cpu_313:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:siemens:simatic_s7-300_cpu_313_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.3.17 OR cpe:2.3:h:siemens:simatic_s7-300_cpu_313:-:*:*:*:*:*:*:*
    Changed CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-300_cpu_314_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-300_cpu_314:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:siemens:simatic_s7-300_cpu_314_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.3.17 OR cpe:2.3:h:siemens:simatic_s7-300_cpu_314:-:*:*:*:*:*:*:*
    Changed CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-300_cpu_314_ifm_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-300_cpu_314_ifm:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:siemens:simatic_s7-300_cpu_314_ifm_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.3.17 OR cpe:2.3:h:siemens:simatic_s7-300_cpu_314_ifm:-:*:*:*:*:*:*:*
    Changed CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-300_cpu_315_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-300_cpu_315:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:siemens:simatic_s7-300_cpu_315_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.3.17 OR cpe:2.3:h:siemens:simatic_s7-300_cpu_315:-:*:*:*:*:*:*:*
    Changed CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_dp_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_dp:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_dp_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.3.17 OR cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_dp:-:*:*:*:*:*:*:*
    Changed CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-300_cpu_316-2_dp_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-300_cpu_316-2_dp:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:siemens:simatic_s7-300_cpu_316-2_dp_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.3.17 OR cpe:2.3:h:siemens:simatic_s7-300_cpu_316-2_dp:-:*:*:*:*:*:*:*
    Changed CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-300_cpu_318-2_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-300_cpu_318-2:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:siemens:simatic_s7-300_cpu_318-2_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 3.3.17 OR cpe:2.3:h:siemens:simatic_s7-300_cpu_318-2:-:*:*:*:*:*:*:*
    Changed CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_winac_rtx_\(f\)_2010_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_winac_rtx_\(f\)_2010:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:siemens:simatic_winac_rtx_\(f\)_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2010 *cpe:2.3:o:siemens:simatic_winac_rtx_\(f\)_firmware:2010:-:*:*:*:*:*:* *cpe:2.3:o:siemens:simatic_winac_rtx_\(f\)_firmware:2010:sp1:*:*:*:*:*:* *cpe:2.3:o:siemens:simatic_winac_rtx_\(f\)_firmware:2010:sp2:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_winac_rtx_\(f\):-:*:*:*:*:*:*:*
    Changed CPE Configuration AND OR *cpe:2.3:o:siemens:sinamics_dcp_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:siemens:sinamics_dcp_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 1.3 OR cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*
    Changed CPE Configuration AND OR *cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 4.8 *cpe:2.3:o:siemens:sinamics_gh150_firmware:4.8:-:*:*:*:*:*:* OR cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*
    Changed CPE Configuration AND OR *cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 4.8 *cpe:2.3:o:siemens:sinamics_gl150_firmware:4.8:-:*:*:*:*:*:* OR cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*
    Changed CPE Configuration AND OR *cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 4.8 *cpe:2.3:o:siemens:sinamics_gm150_firmware:4.8:-:*:*:*:*:*:* OR cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*
    Changed CPE Configuration AND OR *cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 4.7 *cpe:2.3:o:siemens:sinamics_sl150_firmware:4.7:-:*:*:*:*:*:* OR cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*
  • CVE Modified by [email protected]

    Aug. 14, 2020

    Action Type Old Value New Value
    Changed Description A vulnerability has been identified in CP1604 (All versions < V2.8), CP1616 (All versions < V2.8), Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions < V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions < V4.5.0 Patch 01), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions < V4.5.0), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.2.1), SIMATIC CP1604 (All versions < V2.8), SIMATIC CP1616 (All versions < V2.8), SIMATIC ET200M (incl. SIPLUS variants) (All versions), SIMATIC ET200S (incl. SIPLUS variants) (All versions), SIMATIC ET200ecoPN (except 6ES7148-6JD00-0AB0 and 6ES7146-6FF00-0AB0) (All versions), SIMATIC ET200pro (All versions), SIMATIC ET200pro (incl. SIPLUS variants) (All versions), SIMATIC PN/PN Coupler 6ES7158-3AD01-0XA0 (incl. SIPLUS NET variant) (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions < SIMATIC WinAC RTX 2010 SP3), SIMOTION (incl. SIPLUS variants) (All versions), SINAMICS DCM (All versions < V1.5 HF1), SINAMICS DCP (All versions < V1.3), SINAMICS G110M V4.7 Control Unit (All versions < V4.7 SP10 HF5), SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants) (All versions < V4.7 SP10 HF5), SINAMICS G130 V4.7 Control Unit (All versions < V4.7 HF29), SINAMICS G150 Control Unit (All versions < V4.8), SINAMICS GH150 V4.7 Control Unit (All versions), SINAMICS GL150 V4.7 Control Unit (All versions), SINAMICS GM150 V4.7 Control Unit (All versions), SINAMICS S110 Control Unit (All versions), SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants) (All versions < V4.7 HF34), SINAMICS S150 Control Unit (All versions < V4.8), SINAMICS SL150 V4.7 Control Unit (All versions < V4.7 HF33), SINAMICS SM120 V4.7 Control Unit (All versions), SINUMERIK 828D (All versions < V4.8 SP5), SINUMERIK 840D sl (All versions). An attacker with network access to an affected product may cause a Denial-of-Service condition by breaking the real-time synchronization (IRT) of the affected installation. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts the availability of the affected installations. A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions < V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions < V4.5.0 Patch 01), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions < V4.5.0), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.2.1), SIMATIC ET200M (incl. SIPLUS variants) (All versions), SIMATIC ET200S (incl. SIPLUS variants) (All versions), SIMATIC ET200ecoPN (except 6ES7141-6BG00-0BB0, 6ES7141-6BH00-0BB0, 6ES7142-6BG00-0BB0, 6ES7142-6BR00-0BB0, 6ES7143-6BH00-0BB0, 6ES7146-6FF00-0AB0 and 6ES7148-6JD00-0AB0) (All versions), SIMATIC ET200pro (All versions), SIMATIC NET CP 1604 (All versions < V2.8), SIMATIC NET CP 1616 (All versions < V2.8), SIMATIC PN/PN Coupler 6ES7158-3AD01-0XA0 (incl. SIPLUS NET variant) (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions < SIMATIC WinAC RTX 2010 SP3), SIMOTION (incl. SIPLUS variants) (All versions), SINAMICS DCM (All versions < V1.5 HF1), SINAMICS DCP (All versions < V1.3), SINAMICS G110M V4.7 Control Unit (All versions < V4.7 SP10 HF5), SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants) (All versions < V4.7 SP10 HF5), SINAMICS G130 V4.7 Control Unit (All versions < V4.7 HF29), SINAMICS G150 Control Unit (All versions < V4.8), SINAMICS GH150 V4.7 Control Unit (All versions), SINAMICS GL150 V4.7 Control Unit (All versions), SINAMICS GM150 V4.7 Control Unit (All versions), SINAMICS S110 Control Unit (All versions), SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants) (All versions < V4.7 HF34), SINAMICS S150 Control Unit (All versions < V4.8), SINAMICS SL150 V4.7 Control Unit (All versions < V4.7 HF33), SINAMICS SM120 V4.7 Control Unit (All versions), SINUMERIK 828D (All versions < V4.8 SP5), SINUMERIK 840D sl (All versions). An attacker with network access to an affected product may cause a Denial-of-Service condition by breaking the real-time synchronization (IRT) of the affected installation. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts the availability of the affected installations.
  • CVE Modified by [email protected]

    Mar. 10, 2020

    Action Type Old Value New Value
    Changed Description A vulnerability has been identified in CP1604 (All versions < V2.8), CP1616 (All versions < V2.8), Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions < V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions < V4.5.0 Patch 01), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions < V4.5.0), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.2.1), SIMATIC CP1604 (All versions < V2.8), SIMATIC CP1616 (All versions < V2.8), SIMATIC ET200M (incl. SIPLUS variants) (All versions), SIMATIC ET200S (incl. SIPLUS variants) (All versions), SIMATIC ET200ecoPN (except 6ES7148-6JD00-0AB0 and 6ES7146-6FF00-0AB0) (All versions), SIMATIC ET200pro (All versions), SIMATIC ET200pro (incl. SIPLUS variants) (All versions), SIMATIC PN/PN Coupler 6ES7158-3AD01-0XA0 (incl. SIPLUS NET variant) (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions < SIMATIC WinAC RTX 2010 SP3), SIMOTION (incl. SIPLUS variants) (All versions), SINAMICS DCM (All versions < V1.5 HF1), SINAMICS DCP (All versions < V1.3), SINAMICS G110M V4.7 Control Unit (All versions < V4.7 SP10 HF5), SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants) (All versions < V4.7 SP10 HF5), SINAMICS G130 V4.7 Control Unit (All versions < V4.7 HF29), SINAMICS G150 Control Unit (All versions < V4.8), SINAMICS GH150 V4.7 Control Unit (All versions), SINAMICS GL150 V4.7 Control Unit (All versions), SINAMICS GM150 V4.7 Control Unit (All versions), SINAMICS S110 Control Unit (All versions), SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants) (All versions < V4.7 HF34), SINAMICS S150 Control Unit (All versions < V4.8), SINAMICS SL150 V4.7 Control Unit (All versions < V4.7 HF33), SINAMICS SM120 V4.7 Control Unit (All versions), SINUMERIK 828D (All versions < V4.8 SP5), SINUMERIK 840D sl (All versions). An attacker with network access to an affected product may cause a Denial-of-Service condition by breaking the real-time synchronization (IRT) of the affected installation. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts the availability of the affected installations. A vulnerability has been identified in CP1604 (All versions < V2.8), CP1616 (All versions < V2.8), Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions < V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions < V4.5.0 Patch 01), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions < V4.5.0), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.2.1), SIMATIC CP1604 (All versions < V2.8), SIMATIC CP1616 (All versions < V2.8), SIMATIC ET200M (incl. SIPLUS variants) (All versions), SIMATIC ET200S (incl. SIPLUS variants) (All versions), SIMATIC ET200ecoPN (except 6ES7148-6JD00-0AB0 and 6ES7146-6FF00-0AB0) (All versions), SIMATIC ET200pro (All versions), SIMATIC ET200pro (incl. SIPLUS variants) (All versions), SIMATIC PN/PN Coupler 6ES7158-3AD01-0XA0 (incl. SIPLUS NET variant) (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions < SIMATIC WinAC RTX 2010 SP3), SIMOTION (incl. SIPLUS variants) (All versions), SINAMICS DCM (All versions < V1.5 HF1), SINAMICS DCP (All versions < V1.3), SINAMICS G110M V4.7 Control Unit (All versions < V4.7 SP10 HF5), SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants) (All versions < V4.7 SP10 HF5), SINAMICS G130 V4.7 Control Unit (All versions < V4.7 HF29), SINAMICS G150 Control Unit (All versions < V4.8), SINAMICS GH150 V4.7 Control Unit (All versions), SINAMICS GL150 V4.7 Control Unit (All versions), SINAMICS GM150 V4.7 Control Unit (All versions), SINAMICS S110 Control Unit (All versions), SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants) (All versions < V4.7 HF34), SINAMICS S150 Control Unit (All versions < V4.8), SINAMICS SL150 V4.7 Control Unit (All versions < V4.7 HF33), SINAMICS SM120 V4.7 Control Unit (All versions), SINUMERIK 828D (All versions < V4.8 SP5), SINUMERIK 840D sl (All versions). An attacker with network access to an affected product may cause a Denial-of-Service condition by breaking the real-time synchronization (IRT) of the affected installation. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts the availability of the affected installations.
  • CVE Modified by [email protected]

    Feb. 11, 2020

    Action Type Old Value New Value
    Changed Description A vulnerability has been identified in CP1604 (All versions < V2.8), CP1616 (All versions < V2.8), Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions < V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions < V4.5.0 Patch 01), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions < V4.5.0), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.2.1), SIMATIC ET200M (incl. SIPLUS variants) (All versions), SIMATIC ET200S (incl. SIPLUS variants) (All versions), SIMATIC ET200ecoPN (except 6ES7148-6JD00-0AB0 and 6ES7146-6FF00-0AB0) (All versions), SIMATIC ET200pro (incl. SIPLUS variants) (All versions), SIMATIC PN/PN Coupler 6ES7158-3AD01-0XA0 (incl. SIPLUS NET variant) (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions < SIMATIC WinAC RTX 2010 SP3), SIMOTION (incl. SIPLUS variants) (All versions), SINAMICS DCM (All versions < V1.5 HF1), SINAMICS DCP (All versions), SINAMICS G110M V4.7 Control Unit (All versions < V4.7 SP10 HF5), SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants) (All versions < V4.7 SP10 HF5), SINAMICS G130 V4.7 Control Unit (All versions < V4.7 HF29), SINAMICS G150 Control Unit (All versions < V4.8), SINAMICS GH150 V4.7 Control Unit (All versions), SINAMICS GL150 V4.7 Control Unit (All versions), SINAMICS GM150 V4.7 Control Unit (All versions), SINAMICS S110 Control Unit (All versions), SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants) (All versions < V4.7 HF34), SINAMICS S150 Control Unit (All versions < V4.8), SINAMICS SL150 V4.7 Control Unit (All versions < V4.7 HF33), SINAMICS SM120 V4.7 Control Unit (All versions), SINUMERIK 828D (All versions < V4.8 SP5), SINUMERIK 840D sl (All versions). An attacker with network access to an affected product may cause a Denial-of-Service condition by breaking the real-time synchronization (IRT) of the affected installation. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts the availability of the affected installations. A vulnerability has been identified in CP1604 (All versions < V2.8), CP1616 (All versions < V2.8), Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions < V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions < V4.5.0 Patch 01), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions < V4.5.0), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.2.1), SIMATIC CP1604 (All versions < V2.8), SIMATIC CP1616 (All versions < V2.8), SIMATIC ET200M (incl. SIPLUS variants) (All versions), SIMATIC ET200S (incl. SIPLUS variants) (All versions), SIMATIC ET200ecoPN (except 6ES7148-6JD00-0AB0 and 6ES7146-6FF00-0AB0) (All versions), SIMATIC ET200pro (All versions), SIMATIC ET200pro (incl. SIPLUS variants) (All versions), SIMATIC PN/PN Coupler 6ES7158-3AD01-0XA0 (incl. SIPLUS NET variant) (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions < SIMATIC WinAC RTX 2010 SP3), SIMOTION (incl. SIPLUS variants) (All versions), SINAMICS DCM (All versions < V1.5 HF1), SINAMICS DCP (All versions < V1.3), SINAMICS G110M V4.7 Control Unit (All versions < V4.7 SP10 HF5), SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants) (All versions < V4.7 SP10 HF5), SINAMICS G130 V4.7 Control Unit (All versions < V4.7 HF29), SINAMICS G150 Control Unit (All versions < V4.8), SINAMICS GH150 V4.7 Control Unit (All versions), SINAMICS GL150 V4.7 Control Unit (All versions), SINAMICS GM150 V4.7 Control Unit (All versions), SINAMICS S110 Control Unit (All versions), SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants) (All versions < V4.7 HF34), SINAMICS S150 Control Unit (All versions < V4.8), SINAMICS SL150 V4.7 Control Unit (All versions < V4.7 HF33), SINAMICS SM120 V4.7 Control Unit (All versions), SINUMERIK 828D (All versions < V4.8 SP5), SINUMERIK 840D sl (All versions). An attacker with network access to an affected product may cause a Denial-of-Service condition by breaking the real-time synchronization (IRT) of the affected installation. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts the availability of the affected installations.
  • CVE Modified by [email protected]

    Jan. 16, 2020

    Action Type Old Value New Value
    Removed Reference https://www.us-cert.gov/ics/advisories/icsa-19-283-01 [Third Party Advisory, US Government Resource]
  • Initial Analysis by [email protected]

    Oct. 15, 2019

    Action Type Old Value New Value
    Added CVSS V2 NIST (AV:N/AC:L/Au:N/C:N/I:N/A:P)
    Added CVSS V3.1 NIST AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
    Changed Reference Type https://cert-portal.siemens.com/productcert/pdf/ssa-349422.pdf No Types Assigned https://cert-portal.siemens.com/productcert/pdf/ssa-349422.pdf Vendor Advisory
    Changed Reference Type https://www.us-cert.gov/ics/advisories/icsa-19-283-01 No Types Assigned https://www.us-cert.gov/ics/advisories/icsa-19-283-01 Third Party Advisory, US Government Resource
    Added CWE NIST CWE-400
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:cp1604_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.8 OR cpe:2.3:h:siemens:cp1604:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:cp1616_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.8 OR cpe:2.3:h:siemens:cp1616:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 4.1.1 *cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:4.1.1:-:*:*:*:*:*:* *cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:4.1.1:p4:*:*:*:*:*:* OR cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:ek-ertec_200_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 4.5.0 *cpe:2.3:o:siemens:ek-ertec_200_firmware:4.5.0:-:*:*:*:*:*:* OR cpe:2.3:h:siemens:ek-ertec_200:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:ek-ertec_200p_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 4.5.0 OR cpe:2.3:h:siemens:ek-ertec_200p:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:scalance_x-200irt_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 5.2.1 OR cpe:2.3:h:siemens:scalance_x-200irt:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_et_200m_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_et_200s_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_pn\/pn_coupler_6es7158-3ad01-0xa0_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_pn\/pn_coupler_6es7158-3ad01-0xa0:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-300_cpu:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-300_cpu_312_ifm_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-300_cpu_312_ifm:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-300_cpu_313_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-300_cpu_313:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-300_cpu_314_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-300_cpu_314:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-300_cpu_314_ifm_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-300_cpu_314_ifm:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-300_cpu_315_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-300_cpu_315:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_dp_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_dp:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-300_cpu_316-2_dp_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-300_cpu_316-2_dp:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-300_cpu_318-2_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-300_cpu_318-2:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-400_v6_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-400_v6:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-400_pn_v7_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-400_pn_v7:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-400_dp_v7_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_s7-400_dp_v7:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_winac_rtx_\(f\)_2010_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_winac_rtx_\(f\)_2010:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:simotion_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simotion:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:sinamics_dcm_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 1.5 *cpe:2.3:o:siemens:sinamics_dcm_firmware:1.5:-:*:*:*:*:*:* OR cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:sinamics_dcp_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:sinamics_g110m_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 4.7 *cpe:2.3:o:siemens:sinamics_g110m_firmware:4.7:-:*:*:*:*:*:* OR cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:sinamics_g120_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 4.7 *cpe:2.3:o:siemens:sinamics_g120_firmware:4.7:-:*:*:*:*:*:* OR cpe:2.3:h:siemens:sinamics_g120:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 4.7 *cpe:2.3:o:siemens:sinamics_g130_firmware:4.7:-:*:*:*:*:*:* OR cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 4.8 OR cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:sinamics_s110_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:sinamics_s110:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 4.7 *cpe:2.3:o:siemens:sinamics_s120_firmware:4.7:-:*:*:*:*:*:* OR cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 4.8 OR cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*
    Added CPE Configuration AND OR *cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*
    Added CPE Configuration OR *cpe:2.3:a:siemens:sinumerik_828d:*:*:*:*:*:*:*:* versions up to (excluding) 4.8 *cpe:2.3:a:siemens:sinumerik_828d:4.8:-:*:*:*:*:*:* *cpe:2.3:a:siemens:sinumerik_828d:4.8:sp1:*:*:*:*:*:* *cpe:2.3:a:siemens:sinumerik_828d:4.8:sp2:*:*:*:*:*:* *cpe:2.3:a:siemens:sinumerik_828d:4.8:sp3:*:*:*:*:*:* *cpe:2.3:a:siemens:sinumerik_828d:4.8:sp4:*:*:*:*:*:*
    Added CPE Configuration OR *cpe:2.3:a:siemens:sinumerik_840d_sl:*:*:*:*:*:*:*:*
  • CVE Modified by [email protected]

    Oct. 15, 2019

    Action Type Old Value New Value
    Added Reference https://www.us-cert.gov/ics/advisories/icsa-19-283-01 [No Types Assigned]
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days. Following chart shows the EPSS score history of the vulnerability.
CWE - Common Weakness Enumeration

While CVE identifies specific instances of vulnerabilities, CWE categorizes the common flaws or weaknesses that can lead to vulnerabilities. CVE-2019-10923 is associated with the following CWEs:

Common Attack Pattern Enumeration and Classification (CAPEC)

Common Attack Pattern Enumeration and Classification (CAPEC) stores attack patterns, which are descriptions of the common attributes and approaches employed by adversaries to exploit the CVE-2019-10923 weaknesses.

Exploit Prediction

EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days.

0.12 }} 0.00%

score

0.46677

percentile

CVSS31 - Vulnerability Scoring System
Attack Vector
Attack Complexity
Privileges Required
User Interaction
Scope
Confidentiality
Integrity
Availability