9.8
CRITICAL
CVE-2021-20588
Mitsubishi Electric FA Engineering Software TCP/IP Stack Denial of Service/Remote Code Execution
Description

Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.

INFO

Published Date :

Feb. 19, 2021, 8:15 p.m.

Last Modified :

Oct. 18, 2023, 12:15 a.m.

Remotely Exploitable :

Yes !

Impact Score :

5.9

Exploitability Score :

3.9
Public PoC/Exploit Available at Github

CVE-2021-20588 has a 1 public PoC/Exploit available at Github. Go to the Public Exploits tab to see the list.

Affected Products

The following products are affected by CVE-2021-20588 vulnerability. Even if cvefeed.io is aware of the exact versions of the products that are affected, the information is not represented in the table below.

ID Vendor Product Action
1 Mitsubishielectric gx_works3
2 Mitsubishielectric gt_designer3
3 Mitsubishielectric gt_softgot2000
4 Mitsubishielectric cpu_module_logging_configuration_tool
5 Mitsubishielectric cw_configurator
6 Mitsubishielectric gx_logviewer
7 Mitsubishielectric gx_works2
8 Mitsubishielectric m_commdtm-hart
9 Mitsubishielectric m_commdtm-io-link
10 Mitsubishielectric melfa-works
11 Mitsubishielectric melsoft_navigator
12 Mitsubishielectric mi_configurator
13 Mitsubishielectric mt_works2
14 Mitsubishielectric rt_toolbox2
15 Mitsubishielectric rt_toolbox3
16 Mitsubishielectric c_controller_module_setting_and_monitoring_tool
17 Mitsubishielectric data_transfer
18 Mitsubishielectric ezsocket
19 Mitsubishielectric fr_configurator
20 Mitsubishielectric fr_configurator_sw3
21 Mitsubishielectric fr_configurator2
22 Mitsubishielectric gt_softgot1000
23 Mitsubishielectric gx_configurator-dp
24 Mitsubishielectric gx_configurator-qp
25 Mitsubishielectric gx_developer
26 Mitsubishielectric gx_explorer
27 Mitsubishielectric gx_iec_developer
28 Mitsubishielectric gx_remoteservice-i
29 Mitsubishielectric iq_monozukuri_andon
30 Mitsubishielectric iq_monozukuri_process_remote_monitoring
31 Mitsubishielectric melsec_wincpu_setting_utility
32 Mitsubishielectric melsoft_em_software_development_kit
33 Mitsubishielectric mh11_settingtool_version2
34 Mitsubishielectric mx_component
35 Mitsubishielectric network_interface_board_cc-link
36 Mitsubishielectric network_interface_board_cc_ie_control_utility
37 Mitsubishielectric network_interface_board_cc_ie_field_utility
38 Mitsubishielectric network_interface_board_mneth_utility
39 Mitsubishielectric px_developer
40 Mitsubishielectric setting\/monitoring_tools_for_the_c_controller_module
41 Mitsubishielectric slmp_data_collector
References to Advisories, Solutions, and Tools

Here, you will find a curated list of external links that provide in-depth information, practical solutions, and valuable tools related to CVE-2021-20588.

URL Resource
https://jvn.jp/vu/JVNVU92330101/index.html Third Party Advisory
https://www.cisa.gov/news-events/ics-advisories/icsa-21-049-02
https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-021_en.pdf Vendor Advisory

We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).

None

CMake C Python AutoIt

Updated: 3 months, 2 weeks ago
12 stars 2 fork 2 watcher
Born at : Sept. 1, 2021, 3:23 a.m. This repo has been linked 5 different CVEs too.

Results are limited to the first 15 repositories due to potential performance issues.

The following list is the news that have been mention CVE-2021-20588 vulnerability anywhere in the article.

The following table lists the changes that have been made to the CVE-2021-20588 vulnerability over time.

Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.

  • CVE Modified by [email protected]

    May. 14, 2024

    Action Type Old Value New Value
  • CVE Modified by [email protected]

    Oct. 18, 2023

    Action Type Old Value New Value
    Removed Reference https://us-cert.cisa.gov/ics/advisories/icsa-21-049-02 [Third Party Advisory, US Government Resource]
    Added Reference https://www.cisa.gov/news-events/ics-advisories/icsa-21-049-02 [No Types Assigned]
  • CVE Modified by [email protected]

    Nov. 21, 2022

    Action Type Old Value New Value
    Changed Description Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) all versions, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets. Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.
  • CVE Modified by [email protected]

    Jul. 29, 2022

    Action Type Old Value New Value
    Changed Description Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket all versions, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) all versions, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator all versions, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW3PVC-CCPU) all versions, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) all versions and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets. Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) all versions, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.
  • CVE Modified by [email protected]

    May. 25, 2022

    Action Type Old Value New Value
    Changed Description Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(C Controller module setting and monitoring tool all versions, CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket all versions, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link all versions, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) all versions, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator all versions, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility all versions, Network Interface Board CC IE Field Utility all versions, Network Interface Board CC-Link Ver.2 Utility all versions, Network Interface Board MNETH utility all versions, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module all versions, SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets. Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket all versions, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) all versions, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator all versions, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW3PVC-CCPU) all versions, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) all versions and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.
  • Modified Analysis by [email protected]

    May. 12, 2022

    Action Type Old Value New Value
    Changed Reference Type https://us-cert.cisa.gov/ics/advisories/icsa-21-049-02 No Types Assigned https://us-cert.cisa.gov/ics/advisories/icsa-21-049-02 Third Party Advisory, US Government Resource
    Removed CPE Configuration OR *cpe:2.3:a:mitsubishielectric:c_controller_module_setting_and_monitoring_tool:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:data_transfer:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:fr_configurator:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:fr_configurator_sw3:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:gt_got1000:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:gt_got2000:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:gt_softgot1000:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:gt_softgot2000:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:gx_configurator-dp:*:*:*:*:*:*:*:* versions up to (including) 7.14q *cpe:2.3:a:mitsubishielectric:gx_configurator-qp:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:gx_developer:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:gx_explorer:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:gx_iec_developer:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:gx_logviewer:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:gx_remoteservice-i:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:* versions up to (including) 1.597x *cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:* versions up to (including) 1.070y *cpe:2.3:a:mitsubishielectric:m_commdtm-hart:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:m_commdtm-io-link:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:melfa-works:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:melsec_wincpu_setting_utility:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:melsoft_em_software_development_kit:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:melsoft_navigator:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:mh11_settingtool_version2:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:mt_works2:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:network_interface_board_cc-link:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:network_interface_board_cc_ie_control_utility:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:network_interface_board_cc_ie_field_utility:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:network_interface_board_mneth_utility:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:px_developer:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:rt_toolbox2:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:setting\/monitoring_tools_for_the_c_controller_module:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:slmp_data_collector:*:*:*:*:*:*:*:*
    Added CPE Configuration OR *cpe:2.3:a:mitsubishielectric:c_controller_module_setting_and_monitoring_tool:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:*:*:*:*:*:*:*:* versions up to (including) 1.112r *cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:* versions up to (including) 1.011m *cpe:2.3:a:mitsubishielectric:data_transfer:*:*:*:*:*:*:*:* versions up to (including) 3.44w *cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:fr_configurator:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:* versions up to (including) 1.24a *cpe:2.3:a:mitsubishielectric:fr_configurator_sw3:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:gt_designer3:*:*:*:*:*:*:*:* versions up to (including) 1.250l *cpe:2.3:a:mitsubishielectric:gt_softgot1000:*:*:*:*:*:*:*:* versions up to (including) 3.245f *cpe:2.3:a:mitsubishielectric:gt_softgot2000:*:*:*:*:*:*:*:* versions up to (including) 1.250l *cpe:2.3:a:mitsubishielectric:gx_configurator-dp:*:*:*:*:*:*:*:* versions up to (including) 7.14q *cpe:2.3:a:mitsubishielectric:gx_configurator-qp:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:gx_developer:*:*:*:*:*:*:*:* versions up to (including) 8.506c *cpe:2.3:a:mitsubishielectric:gx_explorer:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:gx_iec_developer:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:gx_logviewer:*:*:*:*:*:*:*:* versions up to (including) 1.115u *cpe:2.3:a:mitsubishielectric:gx_remoteservice-i:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:* versions up to (including) 1.597x *cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:* versions up to (including) 1.070y *cpe:2.3:a:mitsubishielectric:iq_monozukuri_andon:-:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:iq_monozukuri_process_remote_monitoring:-:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:m_commdtm-hart:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:m_commdtm-io-link:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:melfa-works:*:*:*:*:*:*:*:* versions up to (including) 4.4 *cpe:2.3:a:mitsubishielectric:melsec_wincpu_setting_utility:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:melsoft_em_software_development_kit:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:melsoft_navigator:*:*:*:*:*:*:*:* versions up to (including) 2.74c *cpe:2.3:a:mitsubishielectric:mh11_settingtool_version2:*:*:*:*:*:*:*:* versions up to (including) 2.004e *cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:mt_works2:*:*:*:*:*:*:*:* versions up to (including) 1.167z *cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:* versions up to (including) 5.001b *cpe:2.3:a:mitsubishielectric:network_interface_board_cc-link:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:network_interface_board_cc_ie_control_utility:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:network_interface_board_cc_ie_field_utility:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:network_interface_board_mneth_utility:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:px_developer:*:*:*:*:*:*:*:* versions up to (including) 1.53f *cpe:2.3:a:mitsubishielectric:rt_toolbox2:*:*:*:*:*:*:*:* versions up to (including) 3.73b *cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:* versions up to (including) 1.82l *cpe:2.3:a:mitsubishielectric:setting\/monitoring_tools_for_the_c_controller_module:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:slmp_data_collector:*:*:*:*:*:*:*:* versions up to (including) 1.04e
  • CWE Remap by [email protected]

    May. 03, 2022

    Action Type Old Value New Value
    Changed CWE CWE-755 CWE-119
  • CVE Modified by [email protected]

    Feb. 09, 2022

    Action Type Old Value New Value
    Changed Description Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(C Controller module setting and monitoring tool all versions, CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket all versions, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link all versions, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) all versions, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator all versions, MT Works2 all versions, MX Component all versions, Network Interface Board CC IE Control utility all versions, Network Interface Board CC IE Field Utility all versions, Network Interface Board CC-Link Ver.2 Utility all versions, Network Interface Board MNETH utility all versions, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module all versions, SLMP Data Collector all versions) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets. Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(C Controller module setting and monitoring tool all versions, CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket all versions, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link all versions, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) all versions, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator all versions, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility all versions, Network Interface Board CC IE Field Utility all versions, Network Interface Board CC-Link Ver.2 Utility all versions, Network Interface Board MNETH utility all versions, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module all versions, SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.
    Added Reference https://us-cert.cisa.gov/ics/advisories/icsa-21-049-02 [No Types Assigned]
  • CVE Modified by [email protected]

    Nov. 19, 2021

    Action Type Old Value New Value
    Changed Description Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(C Controller module setting and monitoring tool all versions, CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket all versions, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link all versions, MELFA-Works all versions, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) all versions, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 all versions, MI Configurator all versions, MT Works2 all versions, MX Component all versions, Network Interface Board CC IE Control utility all versions, Network Interface Board CC IE Field Utility all versions, Network Interface Board CC-Link Ver.2 Utility all versions, Network Interface Board MNETH utility all versions, PX Developer versions 1.53F and prior, RT ToolBox2 all versions, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module all versions, SLMP Data Collector all versions) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets. Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(C Controller module setting and monitoring tool all versions, CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket all versions, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link all versions, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) all versions, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator all versions, MT Works2 all versions, MX Component all versions, Network Interface Board CC IE Control utility all versions, Network Interface Board CC IE Field Utility all versions, Network Interface Board CC-Link Ver.2 Utility all versions, Network Interface Board MNETH utility all versions, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module all versions, SLMP Data Collector all versions) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.
  • CVE Modified by [email protected]

    Aug. 05, 2021

    Action Type Old Value New Value
    Changed Description Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(C Controller module setting and monitoring tool all versions, CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket all versions, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer all versions, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link all versions, MELFA-Works all versions, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) all versions, MELSOFT Navigator all versions, MH11 SettingTool Version2 all versions, MI Configurator all versions, MT Works2 all versions, MX Component all versions, Network Interface Board CC IE Control utility all versions, Network Interface Board CC IE Field Utility all versions, Network Interface Board CC-Link Ver.2 Utility all versions, Network Interface Board MNETH utility all versions, PX Developer versions 1.53F and prior, RT ToolBox2 all versions, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module all versions, SLMP Data Collector all versions) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets. Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(C Controller module setting and monitoring tool all versions, CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket all versions, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link all versions, MELFA-Works all versions, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) all versions, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 all versions, MI Configurator all versions, MT Works2 all versions, MX Component all versions, Network Interface Board CC IE Control utility all versions, Network Interface Board CC IE Field Utility all versions, Network Interface Board CC-Link Ver.2 Utility all versions, Network Interface Board MNETH utility all versions, PX Developer versions 1.53F and prior, RT ToolBox2 all versions, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module all versions, SLMP Data Collector all versions) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.
  • CVE Modified by [email protected]

    Jun. 11, 2021

    Action Type Old Value New Value
    Changed Description Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(C Controller module setting and monitoring tool all versions, CPU Module Logging Configuration Tool all versions, CW Configurator all versions, Data Transfer all versions, EZSocket all versions, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 all versions, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GT SoftGOT1000 Version3 all versions, GT SoftGOT2000 Version1 all versions, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer all versions, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer all versions, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, M_CommDTM-HART all versions, M_CommDTM-IO-Link all versions, MELFA-Works all versions, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) all versions, MELSOFT Navigator all versions, MH11 SettingTool Version2 all versions, MI Configurator all versions, MT Works2 all versions, MX Component all versions, Network Interface Board CC IE Control utility all versions, Network Interface Board CC IE Field Utility all versions, Network Interface Board CC-Link Ver.2 Utility all versions, Network Interface Board MNETH utility all versions, PX Developer all versions, RT ToolBox2 all versions, RT ToolBox3 all versions, Setting/monitoring tools for the C Controller module all versions, SLMP Data Collector all versions) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets. Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(C Controller module setting and monitoring tool all versions, CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket all versions, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer all versions, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link all versions, MELFA-Works all versions, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) all versions, MELSOFT Navigator all versions, MH11 SettingTool Version2 all versions, MI Configurator all versions, MT Works2 all versions, MX Component all versions, Network Interface Board CC IE Control utility all versions, Network Interface Board CC IE Field Utility all versions, Network Interface Board CC-Link Ver.2 Utility all versions, Network Interface Board MNETH utility all versions, PX Developer versions 1.53F and prior, RT ToolBox2 all versions, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module all versions, SLMP Data Collector all versions) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.
  • Initial Analysis by [email protected]

    Mar. 01, 2021

    Action Type Old Value New Value
    Added CVSS V2 NIST (AV:N/AC:L/Au:N/C:P/I:P/A:P)
    Added CVSS V3.1 NIST AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
    Changed Reference Type https://jvn.jp/vu/JVNVU92330101/index.html No Types Assigned https://jvn.jp/vu/JVNVU92330101/index.html Third Party Advisory
    Changed Reference Type https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-021_en.pdf No Types Assigned https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-021_en.pdf Vendor Advisory
    Added CWE NIST CWE-755
    Added CPE Configuration OR *cpe:2.3:a:mitsubishielectric:c_controller_module_setting_and_monitoring_tool:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:data_transfer:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:fr_configurator:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:fr_configurator_sw3:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:gt_got1000:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:gt_got2000:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:gt_softgot1000:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:gt_softgot2000:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:gx_configurator-dp:*:*:*:*:*:*:*:* versions up to (including) 7.14q *cpe:2.3:a:mitsubishielectric:gx_configurator-qp:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:gx_developer:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:gx_explorer:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:gx_iec_developer:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:gx_logviewer:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:gx_remoteservice-i:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:* versions up to (including) 1.597x *cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:* versions up to (including) 1.070y *cpe:2.3:a:mitsubishielectric:m_commdtm-hart:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:m_commdtm-io-link:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:melfa-works:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:melsec_wincpu_setting_utility:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:melsoft_em_software_development_kit:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:melsoft_navigator:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:mh11_settingtool_version2:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:mt_works2:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:network_interface_board_cc-link:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:network_interface_board_cc_ie_control_utility:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:network_interface_board_cc_ie_field_utility:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:network_interface_board_mneth_utility:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:px_developer:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:rt_toolbox2:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:setting\/monitoring_tools_for_the_c_controller_module:*:*:*:*:*:*:*:* *cpe:2.3:a:mitsubishielectric:slmp_data_collector:*:*:*:*:*:*:*:*
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days. Following chart shows the EPSS score history of the vulnerability.
Exploit Prediction

EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days.

0.49 }} 0.05%

score

0.73533

percentile

CVSS31 - Vulnerability Scoring System
Attack Vector
Attack Complexity
Privileges Required
User Interaction
Scope
Confidentiality
Integrity
Availability