CVE-2022-38465
Siemens Simatic Key Exposure Vulnerability
Description
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINUMERIK MC (All versions < V6.21), SINUMERIK ONE (All versions < V6.21). Affected products protect the built-in global private key in a way that cannot be considered sufficient any longer. The key is used for the legacy protection of confidential configuration data and the legacy PG/PC and HMI communication. This could allow attackers to discover the private key of a CPU product family by an offline attack against a single CPU of the family. Attackers could then use this knowledge to extract confidential configuration data from projects that are protected by that key or to perform attacks against legacy PG/PC and HMI communication.
INFO
Published Date :
Oct. 11, 2022, 11:15 a.m.
Last Modified :
Nov. 7, 2023, 3:50 a.m.
Source :
[email protected]
Remotely Exploitable :
No
Impact Score :
6.0
Exploitability Score :
2.5
Affected Products
The following products are affected by CVE-2022-38465
vulnerability.
Even if cvefeed.io
is aware of the exact versions of the
products
that
are
affected, the information is not represented in the table below.
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2022-38465
.
URL | Resource |
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-568427.pdf | Vendor Advisory |
https://cert-portal.siemens.com/productcert/pdf/ssa-568428.pdf |
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2022-38465
vulnerability anywhere in the article.
The following table lists the changes that have been made to the
CVE-2022-38465
vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
CVE Modified by [email protected]
May. 14, 2024
Action Type Old Value New Value -
CVE Modified by [email protected]
Nov. 07, 2023
Action Type Old Value New Value Changed Description A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINUMERIK MC (All versions < V6.21), SINUMERIK ONE (All versions < V6.21). Affected products protect the built-in global private key in a way that cannot be considered sufficient any longer. The key is used for the legacy protection of confidential configuration data and the legacy PG/PC and HMI communication. This could allow attackers to discover the private key of a CPU product family by an offline attack against a single CPU of the family. Attackers could then use this knowledge to extract confidential configuration data from projects that are protected by that key or to perform attacks against legacy PG/PC and HMI communication. A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINUMERIK MC (All versions < V6.21), SINUMERIK ONE (All versions < V6.21). Affected products protect the built-in global private key in a way that cannot be considered sufficient any longer. The key is used for the legacy protection of confidential configuration data and the legacy PG/PC and HMI communication. This could allow attackers to discover the private key of a CPU product family by an offline attack against a single CPU of the family. Attackers could then use this knowledge to extract confidential configuration data from projects that are protected by that key or to perform attacks against legacy PG/PC and HMI communication. -
CVE Modified by [email protected]
Feb. 14, 2023
Action Type Old Value New Value Changed Description A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINUMERIK MC (All versions), SINUMERIK ONE (All versions). Affected products protect the built-in global private key in a way that cannot be considered sufficient any longer. The key is used for the legacy protection of confidential configuration data and the legacy PG/PC and HMI communication. This could allow attackers to discover the private key of a CPU product family by an offline attack against a single CPU of the family. Attackers could then use this knowledge to extract confidential configuration data from projects that are protected by that key or to perform attacks against legacy PG/PC and HMI communication. A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINUMERIK MC (All versions < V6.21), SINUMERIK ONE (All versions < V6.21). Affected products protect the built-in global private key in a way that cannot be considered sufficient any longer. The key is used for the legacy protection of confidential configuration data and the legacy PG/PC and HMI communication. This could allow attackers to discover the private key of a CPU product family by an offline attack against a single CPU of the family. Attackers could then use this knowledge to extract confidential configuration data from projects that are protected by that key or to perform attacks against legacy PG/PC and HMI communication. Added CVSS V3.1 Siemens AG AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H -
CVE Modified by [email protected]
Nov. 08, 2022
Action Type Old Value New Value Changed Description A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0). Affected products protect the built-in global private key in a way that cannot be considered sufficient any longer. The key is used for the legacy protection of confidential configuration data and the legacy PG/PC and HMI communication. This could allow attackers to discover the private key of a CPU product family by an offline attack against a single CPU of the family. Attackers could then use this knowledge to extract confidential configuration data from projects that are protected by that key or to perform attacks against legacy PG/PC and HMI communication. A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINUMERIK MC (All versions), SINUMERIK ONE (All versions). Affected products protect the built-in global private key in a way that cannot be considered sufficient any longer. The key is used for the legacy protection of confidential configuration data and the legacy PG/PC and HMI communication. This could allow attackers to discover the private key of a CPU product family by an offline attack against a single CPU of the family. Attackers could then use this knowledge to extract confidential configuration data from projects that are protected by that key or to perform attacks against legacy PG/PC and HMI communication. Added Reference https://cert-portal.siemens.com/productcert/pdf/ssa-568428.pdf [No Types Assigned] -
Initial Analysis by [email protected]
Oct. 14, 2022
Action Type Old Value New Value Added CVSS V3.1 NIST AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H Changed Reference Type https://cert-portal.siemens.com/productcert/pdf/ssa-568427.pdf No Types Assigned https://cert-portal.siemens.com/productcert/pdf/ssa-568427.pdf Vendor Advisory Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 21.9 OR cpe:2.3:h:siemens:simatic_et_200_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc_firmware:*:*:*:*:*:*:*:* OR cpe:2.3:h:siemens:simatic_et_200_open_controller_cpu_1515sp_pc:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_drive_controller_cpu_1504d_tf_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_drive_controller_cpu_1504d_tf:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_drive_controller_cpu_1507d_tf_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_drive_controller_cpu_1507d_tf:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1211c_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 4.5.0 OR cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1211c:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1212c_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 4.5.0 OR cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1212c:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1212fc_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 4.5.0 OR cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1212fc:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1214fc_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 4.5.0 OR cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1214fc:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1214c_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 4.5.0 OR cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1214c:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1215fc_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 4.5.0 OR cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1215fc:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1215c_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 4.5.0 OR cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1215c:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1217c_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 4.5.0 OR cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1217c:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp-1_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp-1:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511-1_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511-1:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_151511c-1_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_151511c-1:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_151511f-1_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_151511f-1:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511t-1_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511t-1:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511tf-1_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511tf-1:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c-1_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c-1:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512sp-1_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512sp-1:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512spf-1_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512spf-1:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513-1_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513-1:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513f-1_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513f-1:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513r-1_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513r-1:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_15prof-2_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_15prof-2:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_15pro-2_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_15pro-2:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515-2_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515-2:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515f-2_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515f-2:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515r-2_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515r-2:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515t-2_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515t-2:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516pro_f_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516pro_f:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516f-3_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516f-3:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516t-3_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516t-3:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516tf-3_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516tf-3:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517f-3_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517f-3:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518f-4_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518f-4:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518hf-4_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518hf-4:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518t-4_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518t-4:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518tf-4_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.9.2 OR cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518tf-4:-:*:*:*:*:*:*:* Added CPE Configuration OR *cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:* versions up to (excluding) 21.9 Added CPE Configuration AND OR *cpe:2.3:o:siemens:simatic_s7-plcsim_advanced_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 4.0 OR cpe:2.3:h:siemens:simatic_s7-plcsim_advanced:-:*:*:*:*:*:*:*
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2022-38465
is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2022-38465
weaknesses.
Exploit Prediction
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days.
0.04 }} 0.00%
score
0.11794
percentile