CVE-2023-6448
Unitronics Vision PLC and HMI Insecure Default Pas - [Actively Exploited]
Description
Unitronics VisiLogic before version 9.9.00, used in Vision and Samba PLCs and HMIs, uses a default administrative password. An unauthenticated attacker with network access can take administrative control of a vulnerable system.
INFO
Published Date :
Dec. 5, 2023, 6:15 p.m.
Last Modified :
June 26, 2024, 7:59 p.m.
Source :
9119a7d8-5eab-497f-8521-727c672e3725
Remotely Exploitable :
Yes !
Impact Score :
5.9
Exploitability Score :
3.9
CISA KEV (Known Exploited Vulnerabilities)
For the benefit of the cybersecurity community and network defenders—and to help every organization better manage vulnerabilities and keep pace with threat activity—CISA maintains the authoritative source of vulnerabilities that have been exploited in the wild.
Unitronics Vision Series PLCs and HMIs ship with an insecure default password, which if left unchanged, can allow attackers to execute remote commands.
Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.
Note that while it is possible to change the default password, implementors are encouraged to remove affected controllers from public networks and update the affected firmware: https://downloads.unitronicsplc.com/Sites/plc/Technical_Library/Unitronics-Cybersecurity-Advisory-2023-001-CVE-2023-6448.pdf
Public PoC/Exploit Available at Github
CVE-2023-6448 has a 1 public PoC/Exploit
available at Github.
Go to the Public Exploits
tab to see the list.
Affected Products
The following products are affected by CVE-2023-6448
vulnerability.
Even if cvefeed.io
is aware of the exact versions of the
products
that
are
affected, the information is not represented in the table below.
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2023-6448
.
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Ostorlab KEV: One-command to detect most remotely known exploitable vulnerabilities. Sourced from CISA KEV, Google's Tsunami, Ostorlab's Asteroid and Bug Bounty programs.
cisa-kev vulnerability 0day cisa exploits
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2023-6448
vulnerability anywhere in the article.
- security.nl
VS publiceert overzicht van meest misbruikte kwetsbaarheden in 2023
De Amerikaanse autoriteiten hebben samen met cyberagentschappen uit Australië, Canada, Nieuw-Zeeland en het Verenigd Koninkrijk een overzicht van de meest misbruikte kwetsbaarheden in 2023 opgesteld. ... Read more
- Cybersecurity News
Team82 Unveils Research on Unitronics PLC/HMI Attacks Targeting Critical Infrastructure
A defaced Unitronics integrated HMI/PLC. (Source: Unitronics)Recently, the cybersecurity research team known as Team82 has published an in-depth investigation into a series of cyberattacks targeting i ... Read more
The following table lists the changes that have been made to the
CVE-2023-6448
vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
Modified Analysis by [email protected]
Jun. 26, 2024
Action Type Old Value New Value Changed Reference Type https://downloads.unitronicsplc.com/Sites/plc/Technical_Library/Unitronics-Cybersecurity-Advisory-2023-001-CVE-2023-6448.pdf No Types Assigned https://downloads.unitronicsplc.com/Sites/plc/Technical_Library/Unitronics-Cybersecurity-Advisory-2023-001-CVE-2023-6448.pdf Vendor Advisory Changed Reference Type https://downloads.unitronicsplc.com/Sites/plc/Visilogic/Version_Changes-Bug_Reports/VisiLogic%209.9.00%20Version%20changes.pdf No Types Assigned https://downloads.unitronicsplc.com/Sites/plc/Visilogic/Version_Changes-Bug_Reports/VisiLogic%209.9.00%20Version%20changes.pdf Release Notes Changed Reference Type https://www.unitronicsplc.com/cyber_security_vision-samba/ No Types Assigned https://www.unitronicsplc.com/cyber_security_vision-samba/ Product Changed CPE Configuration AND OR cpe:2.3:h:unitronics:vision1210:-:*:*:*:*:*:*:* OR *cpe:2.3:o:unitronics:vision1210_firmware:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:unitronics:vision1210_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 12.38 OR cpe:2.3:h:unitronics:vision1210:-:*:*:*:*:*:*:* Changed CPE Configuration AND OR cpe:2.3:h:unitronics:vision1040:-:*:*:*:*:*:*:* OR *cpe:2.3:o:unitronics:vision1040_firmware:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:unitronics:vision1040_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 12.38 OR cpe:2.3:h:unitronics:vision1040:-:*:*:*:*:*:*:* Changed CPE Configuration AND OR cpe:2.3:h:unitronics:vision700:-:*:*:*:*:*:*:* OR *cpe:2.3:o:unitronics:vision700_firmware:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:unitronics:vision700_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 12.38 OR cpe:2.3:h:unitronics:vision700:-:*:*:*:*:*:*:* Changed CPE Configuration AND OR cpe:2.3:h:unitronics:vision570:-:*:*:*:*:*:*:* OR *cpe:2.3:o:unitronics:vision570_firmware:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:unitronics:vision570_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 12.38 OR cpe:2.3:h:unitronics:vision570:-:*:*:*:*:*:*:* Changed CPE Configuration AND OR cpe:2.3:h:unitronics:vision560:-:*:*:*:*:*:*:* OR *cpe:2.3:o:unitronics:vision560_firmware:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:unitronics:vision560_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 12.38 OR cpe:2.3:h:unitronics:vision560:-:*:*:*:*:*:*:* Changed CPE Configuration AND OR cpe:2.3:h:unitronics:vision430:-:*:*:*:*:*:*:* OR *cpe:2.3:o:unitronics:vision430_firmware:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:unitronics:vision430_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 12.38 OR cpe:2.3:h:unitronics:vision430:-:*:*:*:*:*:*:* Changed CPE Configuration AND OR cpe:2.3:h:unitronics:vision350:-:*:*:*:*:*:*:* OR *cpe:2.3:o:unitronics:vision350_firmware:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:unitronics:vision350_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 12.38 OR cpe:2.3:h:unitronics:vision350:-:*:*:*:*:*:*:* Changed CPE Configuration AND OR *cpe:2.3:o:unitronics:vision130_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:unitronics:vision130:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:unitronics:vision130_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 12.38 OR cpe:2.3:h:unitronics:vision130:-:*:*:*:*:*:*:* Changed CPE Configuration AND OR *cpe:2.3:o:unitronics:vision230_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:unitronics:vision230:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:unitronics:vision230_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 12.38 OR cpe:2.3:h:unitronics:vision230:-:*:*:*:*:*:*:* Changed CPE Configuration AND OR *cpe:2.3:o:unitronics:vision280_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:unitronics:vision280:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:unitronics:vision280_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 12.38 OR cpe:2.3:h:unitronics:vision280:-:*:*:*:*:*:*:* Changed CPE Configuration AND OR *cpe:2.3:o:unitronics:vision290_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:unitronics:vision290:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:unitronics:vision290_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 12.38 OR cpe:2.3:h:unitronics:vision290:-:*:*:*:*:*:*:* Changed CPE Configuration AND OR *cpe:2.3:o:unitronics:vision530_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:unitronics:vision530:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:unitronics:vision530_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 12.38 OR cpe:2.3:h:unitronics:vision530:-:*:*:*:*:*:*:* Changed CPE Configuration AND OR *cpe:2.3:o:unitronics:vision120_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:unitronics:vision120:-:*:*:*:*:*:*:* AND OR *cpe:2.3:o:unitronics:vision120_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 12.38 OR cpe:2.3:h:unitronics:vision120:-:*:*:*:*:*:*:* Added CPE Configuration OR *cpe:2.3:a:unitronics:visilogic:*:*:*:*:*:*:*:* versions up to (excluding) 9.9.00 Added CPE Configuration AND OR *cpe:2.3:o:unitronics:samba_3.5_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 12.38 OR cpe:2.3:h:unitronics:samba_3.5:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:unitronics:samba_4.3_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 12.38 OR cpe:2.3:h:unitronics:samba_4.3:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:unitronics:samba_7_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 12.38 OR cpe:2.3:h:unitronics:samba_7:-:*:*:*:*:*:*:* -
CVE Modified by 9119a7d8-5eab-497f-8521-727c672e3725
May. 14, 2024
Action Type Old Value New Value -
CVE Modified by 9119a7d8-5eab-497f-8521-727c672e3725
Dec. 19, 2023
Action Type Old Value New Value Added Reference Cybersecurity and Infrastructure Security Agency (CISA) U.S. Civilian Government https://downloads.unitronicsplc.com/Sites/plc/Technical_Library/Unitronics-Cybersecurity-Advisory-2023-001-CVE-2023-6448.pdf [No types assigned] -
CVE Modified by 9119a7d8-5eab-497f-8521-727c672e3725
Dec. 13, 2023
Action Type Old Value New Value Changed Description Unitronics Vision Series PLCs and HMIs use default administrative passwords. An unauthenticated attacker with network access to a PLC or HMI can take administrative control of the system. Unitronics VisiLogic before version 9.9.00, used in Vision and Samba PLCs and HMIs, uses a default administrative password. An unauthenticated attacker with network access can take administrative control of a vulnerable system. -
CVE Modified by 9119a7d8-5eab-497f-8521-727c672e3725
Dec. 13, 2023
Action Type Old Value New Value Added Reference Cybersecurity and Infrastructure Security Agency (CISA) U.S. Civilian Government https://www.unitronicsplc.com/cyber_security_vision-samba/ [No types assigned] Added Reference Cybersecurity and Infrastructure Security Agency (CISA) U.S. Civilian Government https://downloads.unitronicsplc.com/Sites/plc/Visilogic/Version_Changes-Bug_Reports/VisiLogic%209.9.00%20Version%20changes.pdf [No types assigned] -
Initial Analysis by [email protected]
Dec. 12, 2023
Action Type Old Value New Value Added CVSS V3.1 NIST AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Changed Reference Type https://www.cisa.gov/news-events/alerts/2023/11/28/exploitation-unitronics-plcs-used-water-and-wastewater-systems No Types Assigned https://www.cisa.gov/news-events/alerts/2023/11/28/exploitation-unitronics-plcs-used-water-and-wastewater-systems Third Party Advisory, US Government Resource Added CWE NIST CWE-798 Added CPE Configuration AND OR *cpe:2.3:o:unitronics:vision1210_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:unitronics:vision1210:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:unitronics:vision1040_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:unitronics:vision1040:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:unitronics:vision700_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:unitronics:vision700:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:unitronics:vision570_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:unitronics:vision570:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:unitronics:vision560_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:unitronics:vision560:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:unitronics:vision430_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:unitronics:vision430:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:unitronics:vision350_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:unitronics:vision350:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:unitronics:vision130_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:unitronics:vision130:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:unitronics:vision230_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:unitronics:vision230:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:unitronics:vision280_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:unitronics:vision280:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:unitronics:vision290_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:unitronics:vision290:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:unitronics:vision530_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:unitronics:vision530:-:*:*:*:*:*:*:* Added CPE Configuration AND OR *cpe:2.3:o:unitronics:vision120_firmware:-:*:*:*:*:*:*:* OR cpe:2.3:h:unitronics:vision120:-:*:*:*:*:*:*:* -
CVE Received by 9119a7d8-5eab-497f-8521-727c672e3725
Dec. 05, 2023
Action Type Old Value New Value Added Description Unitronics Vision Series PLCs and HMIs use default administrative passwords. An unauthenticated attacker with network access to a PLC or HMI can take administrative control of the system. Added Reference Cybersecurity and Infrastructure Security Agency (CISA) U.S. Civilian Government https://www.cisa.gov/news-events/alerts/2023/11/28/exploitation-unitronics-plcs-used-water-and-wastewater-systems [No types assigned] Added CWE Cybersecurity and Infrastructure Security Agency (CISA) U.S. Civilian Government CWE-1188 Added CVSS V3.1 Cybersecurity and Infrastructure Security Agency (CISA) U.S. Civilian Government AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2023-6448
is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2023-6448
weaknesses.
Exploit Prediction
EPSS is a daily estimate of the probability of exploitation activity being observed over the next 30 days.
2.93 }} -0.52%
score
0.91091
percentile