CVE-2025-40800
COMOS NX Simcenter Solid Edge TLS Certificate Validation Bypass
Description
A vulnerability has been identified in COMOS V10.6 (All versions), COMOS V10.6 (All versions), NX V2412 (All versions < V2412.8700), NX V2506 (All versions < V2506.6000), Simcenter 3D (All versions < V2506.6000), Simcenter Femap (All versions < V2506.0002), Solid Edge SE2025 (All versions < V225.0 Update 10), Solid Edge SE2026 (All versions < V226.0 Update 1). The IAM client in affected products is missing server certificate validation while establishing TLS connections to the authorization server. This could allow an attacker to perform a man-in-the-middle attack.
INFO
Published Date :
Dec. 9, 2025, 4:17 p.m.
Last Modified :
Dec. 9, 2025, 6:36 p.m.
Remotely Exploit :
Yes !
Source :
[email protected]
Affected Products
The following products are affected by CVE-2025-40800
vulnerability.
Even if cvefeed.io is aware of the exact versions of the
products
that
are
affected, the information is not represented in the table below.
CVSS Scores
| Score | Version | Severity | Vector | Exploitability Score | Impact Score | Source |
|---|---|---|---|---|---|---|
| CVSS 3.1 | HIGH | MITRE-CVE | ||||
| CVSS 3.1 | HIGH | [email protected] | ||||
| CVSS 4.0 | CRITICAL | [email protected] |
Solution
- Update COMOS to V10.6.
- Update NX to V2412.8700 or later.
- Update NX to V2506.6000 or later.
- Update Simcenter 3D to V2506.6000 or later.
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2025-40800.
| URL | Resource |
|---|---|
| https://cert-portal.siemens.com/productcert/html/ssa-212953.html | |
| https://cert-portal.siemens.com/productcert/html/ssa-868571.html |
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2025-40800 is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2025-40800
weaknesses.
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2025-40800 vulnerability anywhere in the article.
The following table lists the changes that have been made to the
CVE-2025-40800 vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
New CVE Received by [email protected]
Dec. 09, 2025
Action Type Old Value New Value Added Description A vulnerability has been identified in COMOS V10.6 (All versions), COMOS V10.6 (All versions), NX V2412 (All versions < V2412.8700), NX V2506 (All versions < V2506.6000), Simcenter 3D (All versions < V2506.6000), Simcenter Femap (All versions < V2506.0002), Solid Edge SE2025 (All versions < V225.0 Update 10), Solid Edge SE2026 (All versions < V226.0 Update 1). The IAM client in affected products is missing server certificate validation while establishing TLS connections to the authorization server. This could allow an attacker to perform a man-in-the-middle attack. Added CVSS V4.0 AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X Added CVSS V3.1 AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N Added CWE CWE-295 Added Reference https://cert-portal.siemens.com/productcert/html/ssa-212953.html Added Reference https://cert-portal.siemens.com/productcert/html/ssa-868571.html