CVE-2026-34765
Electron named window.open targets not scoped to the opener's browsing context
Description
Electron is a framework for writing cross-platform desktop applications using JavaScript, HTML and CSS. Prior to 39.8.5, 40.8.5, 41.1.0, and 42.0.0-alpha.5, when a renderer calls window.open() with a target name, Electron did not correctly scope the named-window lookup to the opener's browsing context group. A renderer could navigate an existing child window that was opened by a different, unrelated renderer if both used the same target name. If that existing child was created with more permissive webPreferences (via setWindowOpenHandler's overrideBrowserWindowOptions), content loaded by the second renderer inherits those permissions. Apps are only affected if they open multiple top-level windows with differing trust levels and use setWindowOpenHandler to grant child windows elevated webPreferences such as a privileged preload script. Apps that do not elevate child window privileges, or that use a single top-level window, are not affected. Apps that additionally grant nodeIntegration: true or sandbox: false to child windows (contrary to the security recommendations) may be exposed to arbitrary code execution. This vulnerability is fixed in 39.8.5, 40.8.5, 41.1.0, and 42.0.0-alpha.5.
INFO
Published Date :
April 7, 2026, 10:16 p.m.
Last Modified :
April 7, 2026, 10:16 p.m.
Remotely Exploit :
Yes !
Source :
[email protected]
Affected Products
The following products are affected by CVE-2026-34765
vulnerability.
Even if cvefeed.io is aware of the exact versions of the
products
that
are
affected, the information is not represented in the table below.
No affected product recoded yet
CVSS Scores
| Score | Version | Severity | Vector | Exploitability Score | Impact Score | Source |
|---|---|---|---|---|---|---|
| CVSS 3.1 | MEDIUM | [email protected] |
Solution
- Update Electron to version 39.8.5 or later.
- Update Electron to version 40.8.5 or later.
- Update Electron to version 41.1.0 or later.
- Update Electron to version 42.0.0-alpha.5 or later.
References to Advisories, Solutions, and Tools
Here, you will find a curated list of external links that provide in-depth
information, practical solutions, and valuable tools related to
CVE-2026-34765.
| URL | Resource |
|---|---|
| https://github.com/electron/electron/security/advisories/GHSA-f3pv-wv63-48x8 |
CWE - Common Weakness Enumeration
While CVE identifies
specific instances of vulnerabilities, CWE categorizes the common flaws or
weaknesses that can lead to vulnerabilities. CVE-2026-34765 is
associated with the following CWEs:
Common Attack Pattern Enumeration and Classification (CAPEC)
Common Attack Pattern Enumeration and Classification
(CAPEC)
stores attack patterns, which are descriptions of the common attributes and
approaches employed by adversaries to exploit the CVE-2026-34765
weaknesses.
We scan GitHub repositories to detect new proof-of-concept exploits. Following list is a collection of public exploits and proof-of-concepts, which have been published on GitHub (sorted by the most recently updated).
Results are limited to the first 15 repositories due to potential performance issues.
The following list is the news that have been mention
CVE-2026-34765 vulnerability anywhere in the article.
The following table lists the changes that have been made to the
CVE-2026-34765 vulnerability over time.
Vulnerability history details can be useful for understanding the evolution of a vulnerability, and for identifying the most recent changes that may impact the vulnerability's severity, exploitability, or other characteristics.
-
New CVE Received by [email protected]
Apr. 07, 2026
Action Type Old Value New Value Added Description Electron is a framework for writing cross-platform desktop applications using JavaScript, HTML and CSS. Prior to 39.8.5, 40.8.5, 41.1.0, and 42.0.0-alpha.5, when a renderer calls window.open() with a target name, Electron did not correctly scope the named-window lookup to the opener's browsing context group. A renderer could navigate an existing child window that was opened by a different, unrelated renderer if both used the same target name. If that existing child was created with more permissive webPreferences (via setWindowOpenHandler's overrideBrowserWindowOptions), content loaded by the second renderer inherits those permissions. Apps are only affected if they open multiple top-level windows with differing trust levels and use setWindowOpenHandler to grant child windows elevated webPreferences such as a privileged preload script. Apps that do not elevate child window privileges, or that use a single top-level window, are not affected. Apps that additionally grant nodeIntegration: true or sandbox: false to child windows (contrary to the security recommendations) may be exposed to arbitrary code execution. This vulnerability is fixed in 39.8.5, 40.8.5, 41.1.0, and 42.0.0-alpha.5. Added CVSS V3.1 AV:N/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:L Added CWE CWE-668 Added Reference https://github.com/electron/electron/security/advisories/GHSA-f3pv-wv63-48x8