Latest CVE Feed
-
6.1
MEDIUMCVE-2025-63725
Reflected Cross-Site Scripting (XSS) vulnerability in SVX Portal 2.7A via the id parameter to Recivers.php.... Read more
Affected Products :- Published: Nov. 14, 2025
- Modified: Nov. 18, 2025
- Vuln Type: Cross-Site Scripting
-
5.5
MEDIUMCVE-2025-13221
A weakness has been identified in Intelbras UnniTI 24.07.11. The affected element is an unknown function of the file /xml/sistema/usuarios.xml. Executing manipulation of the argument Usuario/Senha can lead to unprotected storage of credentials. The attack... Read more
Affected Products :- Published: Nov. 15, 2025
- Modified: Nov. 18, 2025
- Vuln Type: Misconfiguration
-
4.3
MEDIUMCVE-2025-12182
The Qi Blocks plugin for WordPress is vulnerable to unauthorized access due to a missing capability check on the `resize_image_callback()` function in all versions up to, and including, 1.4.3. This is due to the plugin not properly verifying that a user h... Read more
Affected Products : qi_blocks- Published: Nov. 15, 2025
- Modified: Nov. 18, 2025
- Vuln Type: Authorization
-
8.4
HIGHCVE-2025-9317
The vulnerability, if exploited, could allow a miscreant with read access to Edge Project files or Edge Offline Cache files to reverse engineer Edge users' app-native or Active Directory passwords through computational brute-forcing of weak hashes.... Read more
Affected Products : aveva_edge- Published: Nov. 15, 2025
- Modified: Nov. 18, 2025
- Vuln Type: Information Disclosure
-
8.8
HIGHCVE-2025-55034
General Industrial Controls Lynx+ Gateway is vulnerable to a weak password requirement vulnerability, which may allow an attacker to execute a brute-force attack resulting in unauthorized access and login.... Read more
Affected Products :- Published: Nov. 15, 2025
- Modified: Nov. 18, 2025
- Vuln Type: Authentication
-
7.5
HIGHCVE-2025-13033
A vulnerability was identified in the email parsing library due to improper handling of specially formatted recipient email addresses. An attacker can exploit this flaw by crafting a recipient address that embeds an external address within quotes. This ca... Read more
Affected Products : nodemailer- Published: Nov. 14, 2025
- Modified: Nov. 18, 2025
- Vuln Type: Information Disclosure
-
8.6
HIGHCVE-2025-63680
Nero BackItUp in the Nero Productline is vulnerable to a path parsing/UI rendering flaw (CWE-22) that, in combination with Windows ShellExecuteW fallback extension resolution, leads to arbitrary code execution when a user clicks a crafted entry. By creati... Read more
Affected Products :- Published: Nov. 14, 2025
- Modified: Nov. 18, 2025
- Vuln Type: Path Traversal
-
6.5
MEDIUMCVE-2025-13174
A weakness has been identified in rachelos WeRSS we-mp-rss up to 1.4.7. Affected by this vulnerability is the function do_job of the file /rachelos/we-mp-rss/blob/main/jobs/mps.py of the component Webhook Module. Executing manipulation of the argument web... Read more
Affected Products :- Published: Nov. 14, 2025
- Modified: Nov. 18, 2025
- Vuln Type: Server-Side Request Forgery
-
7.5
HIGHCVE-2025-12482
The Booking for Appointments and Events Calendar – Amelia plugin for WordPress is vulnerable to SQL Injection via the ‘search’ parameter in all versions up to, and including, 1.2.35 due to insufficient escaping on the user supplied parameter and lack of s... Read more
Affected Products : amelia- Published: Nov. 16, 2025
- Modified: Nov. 18, 2025
- Vuln Type: Injection
-
7.2
HIGHCVE-2025-8386
The vulnerability, if exploited, could allow an authenticated miscreant (with privilege of "aaConfigTools") to tamper with App Objects' help files and persist a cross-site scripting (XSS) injection that when executed by a victim user, can result in hor... Read more
Affected Products :- Published: Nov. 15, 2025
- Modified: Nov. 18, 2025
- Vuln Type: Cross-Site Scripting
-
1.1
LOWCVE-2025-4617
An insufficient policy enforcement vulnerability in Palo Alto Networks Prisma® Browser on Windows allows a locally authenticated non-admin user to bypass the screenshot control feature of the browser. Browser self-protection should be enabled to mitigat... Read more
Affected Products : prisma_browser- Published: Nov. 14, 2025
- Modified: Nov. 18, 2025
- Vuln Type: Misconfiguration
-
8.7
HIGHCVE-2021-4468
PLANEX CS-QP50F-ING2 smart cameras expose a configuration backup interface over HTTP that does not require authentication. A remote, unauthenticated attacker can directly retrieve a compressed configuration backup file from the device. The backup contains... Read more
Affected Products :- Published: Nov. 14, 2025
- Modified: Nov. 18, 2025
- Vuln Type: Authentication
-
5.1
MEDIUMCVE-2025-13232
A flaw has been found in projectsend up to r1720. Impacted is an unknown function of the component File Editor/Custom Download Aliases. This manipulation causes cross site scripting. The attack is possible to be carried out remotely. The exploit has been ... Read more
Affected Products : projectsend- Published: Nov. 16, 2025
- Modified: Nov. 18, 2025
- Vuln Type: Cross-Site Scripting
-
4.4
MEDIUMCVE-2025-4618
A sensitive information disclosure vulnerability in Palo Alto Networks Prisma® Browser allows a locally authenticated non-admin user to retrieve sensitive data from Prisma Browser. Browser self-protection should be enabled to mitigate this issue.... Read more
Affected Products : prisma_browser- Published: Nov. 14, 2025
- Modified: Nov. 18, 2025
- Vuln Type: Information Disclosure
-
1.1
LOWCVE-2025-4616
An insufficient validation of an untrusted input vulnerability in Palo Alto Networks Prisma® Browser allows a locally authenticated non-admin user to revert the browser’s security controls.... Read more
Affected Products :- Published: Nov. 14, 2025
- Modified: Nov. 18, 2025
- Vuln Type: Misconfiguration
-
8.6
HIGHCVE-2025-64309
Brightpick Mission Control discloses device telemetry, configuration, and credential information via WebSocket traffic to unauthenticated users when they connect to a specific URL. The unauthenticated URL can be discovered through basic network scanni... Read more
Affected Products :- Published: Nov. 15, 2025
- Modified: Nov. 18, 2025
- Vuln Type: Information Disclosure
-
8.7
HIGHCVE-2025-59780
General Industrial Controls Lynx+ Gateway is missing critical authentication in the embedded web server which could allow an attacker to send GET requests to obtain sensitive device information.... Read more
Affected Products :- Published: Nov. 15, 2025
- Modified: Nov. 18, 2025
- Vuln Type: Authentication
-
7.1
HIGHCVE-2025-64307
The Brightpick Internal Logic Control web interface is accessible without requiring user authentication. An unauthorized user could exploit this interface to manipulate robot control functions, including initiating or halting runners, assigning jobs, c... Read more
Affected Products :- Published: Nov. 15, 2025
- Modified: Nov. 18, 2025
- Vuln Type: Authentication
-
8.7
HIGHCVE-2021-4471
TG8 Firewall exposes a directory such as /data/ over HTTP without authentication. This directory stores credential files for previously logged-in users. A remote unauthenticated attacker can enumerate and download files within the directory to obtain vali... Read more
Affected Products : tg8_firewall- Published: Nov. 14, 2025
- Modified: Nov. 18, 2025
- Vuln Type: Authentication
-
8.7
HIGHCVE-2018-25125
Netis ADSL Router DL4322D firmware RTK 2.1.1 contains a buffer overflow vulnerability in the embedded FTP service that allows an authenticated remote user to trigger a denial of service. After logging in to the FTP service, sending an FTP command such as ... Read more
Affected Products : dl4343_firmware- Published: Nov. 14, 2025
- Modified: Nov. 18, 2025
- Vuln Type: Denial of Service