Latest CVE Feed
-
4.2
MEDIUMCVE-2024-21808
Improper buffer restrictions in some Intel(R) VPL software before version 24.1.4 may allow an authenticated user to potentially enable escalation of privilege via local access.... Read more
Affected Products :- Published: Nov. 13, 2024
- Modified: Nov. 15, 2024
-
2.2
LOWCVE-2024-28030
NULL pointer dereference in some Intel(R) VPL software before version 24.1.4 may allow an authenticated user to potentially enable denial of service via local access.... Read more
Affected Products :- Published: Nov. 13, 2024
- Modified: Nov. 15, 2024
-
6.7
MEDIUMCVE-2024-23312
Uncontrolled search path for some Intel(R) Binary Configuration Tool software for Windows before version 3.4.5 may allow an authenticated user to potentially enable escalation of privilege via local access.... Read more
Affected Products :- Published: Nov. 13, 2024
- Modified: Nov. 15, 2024
-
8.8
HIGHCVE-2024-23918
Improper conditions check in some Intel(R) Xeon(R) processor memory controller configurations when using Intel(R) SGX may allow a privileged user to potentially enable escalation of privilege via local access.... Read more
Affected Products :- Published: Nov. 13, 2024
- Modified: Nov. 15, 2024
-
8.0
HIGHCVE-2024-52551
Jenkins Pipeline: Declarative Plugin 2.2214.vb_b_34b_2ea_9b_83 and earlier does not check whether the main (Jenkinsfile) script used to restart a build from a specific stage is approved, allowing attackers with Item/Build permission to restart a previous ... Read more
Affected Products :- Published: Nov. 13, 2024
- Modified: Nov. 15, 2024
-
8.0
HIGHCVE-2024-52552
Jenkins Authorize Project Plugin 1.7.2 and earlier evaluates a string containing the job name with JavaScript on the Authorization view, resulting in a stored cross-site scripting (XSS) vulnerability exploitable by attackers with Item/Configure permission... Read more
Affected Products :- Published: Nov. 13, 2024
- Modified: Nov. 15, 2024
-
8.8
HIGHCVE-2024-52554
Jenkins Shared Library Version Override Plugin 17.v786074c9fce7 and earlier declares folder-scoped library overrides as trusted, so that they're not executed in the Script Security sandbox, allowing attackers with Item/Configure permission on a folder to ... Read more
Affected Products :- Published: Nov. 13, 2024
- Modified: Nov. 15, 2024
-
9.1
CRITICALCVE-2024-37285
A deserialization issue in Kibana can lead to arbitrary code execution when Kibana attempts to parse a YAML document containing a crafted payload. A successful attack requires a malicious user to have a combination of both specific Elasticsearch indices ... Read more
Affected Products : kibana- Published: Nov. 14, 2024
- Modified: Nov. 15, 2024
-
6.7
MEDIUMCVE-2023-34049
The Salt-SSH pre-flight option copies the script to the target at a predictable path, which allows an attacker to force Salt-SSH to run their script. If an attacker has access to the target VM and knows the path to the pre-flight script before it runs the... Read more
Affected Products :- Published: Nov. 14, 2024
- Modified: Nov. 15, 2024
-
8.2
HIGHCVE-2024-11136
The default TCL Camera application exposes a provider vulnerable to path traversal vulnerability. Malicious application can supply malicious URI path and delete arbitrary files from user’s external storage.... Read more
Affected Products :- Published: Nov. 14, 2024
- Modified: Nov. 15, 2024
-
10.0
CRITICALCVE-2024-48966
The software tools used by service personnel to test & calibrate the ventilator do not support user authentication. An attacker with access to the Service PC where the tools are installed could obtain diagnostic information through the test tool or manipu... Read more
Affected Products :- Published: Nov. 14, 2024
- Modified: Nov. 15, 2024
-
9.3
CRITICALCVE-2024-48973
The debug port on the ventilator's serial interface is enabled by default. This could allow an attacker to send and receive messages over the debug port (which are unencrypted; see 3.2.1) that result in unauthorized disclosure of information and/or have u... Read more
Affected Products :- Published: Nov. 14, 2024
- Modified: Nov. 15, 2024
-
7.5
HIGHCVE-2022-2232
A flaw was found in the Keycloak package. This flaw allows an attacker to utilize an LDAP injection to bypass the username lookup or potentially perform other malicious actions.... Read more
- Published: Nov. 14, 2024
- Modified: Nov. 15, 2024
-
6.5
MEDIUMCVE-2024-11215
Absolute path traversal (incorrect restriction of a path to a restricted directory) vulnerability in the EasyPHP web server, affecting version 14.1. This vulnerability could allow remote users to bypass SecurityManager restrictions and retrieve any file s... Read more
Affected Products :- Published: Nov. 14, 2024
- Modified: Nov. 15, 2024
-
10.0
CRITICALCVE-2024-52374
Unrestricted Upload of File with Dangerous Type vulnerability in DoThatTask Do That Task allows Upload a Web Shell to a Web Server.This issue affects Do That Task: from n/a through 1.5.5.... Read more
Affected Products :- Published: Nov. 14, 2024
- Modified: Nov. 15, 2024
-
9.9
CRITICALCVE-2024-52369
Unrestricted Upload of File with Dangerous Type vulnerability in Optimal Access Inc. KBucket allows Upload a Web Shell to a Web Server.This issue affects KBucket: from n/a through 4.1.6.... Read more
Affected Products :- Published: Nov. 14, 2024
- Modified: Nov. 15, 2024
-
9.3
CRITICALCVE-2024-9832
There is no limit on the number of failed login attempts permitted with the Clinician Password or the Serial Number Clinician Password. An attacker could execute a brute-force attack to gain unauthorized access to the ventilator, and then make changes to ... Read more
Affected Products :- Published: Nov. 14, 2024
- Modified: Nov. 15, 2024
-
7.1
HIGHCVE-2024-51658
Cross-Site Request Forgery (CSRF) vulnerability in Henrik Hoff WP Course Manager allows Stored XSS.This issue affects WP Course Manager: from n/a through 1.3.... Read more
Affected Products :- Published: Nov. 14, 2024
- Modified: Nov. 15, 2024
-
10.0
CRITICALCVE-2024-48967
The ventilator and the Service PC lack sufficient audit logging capabilities to allow for detection of malicious activity and subsequent forensic examination. An attacker with access to the ventilator and/or the Service PC could, without detection, make u... Read more
Affected Products :- Published: Nov. 14, 2024
- Modified: Nov. 15, 2024
-
7.3
HIGHCVE-2024-6068
A memory corruption vulnerability exists in the affected products when parsing DFT files. Local threat actors can exploit this issue to disclose information and to execute arbitrary code. To exploit this vulnerability a legitimate user must open a malici... Read more
Affected Products :- Published: Nov. 14, 2024
- Modified: Nov. 15, 2024